Platelet function testing is often affected by the existence of different pre-analytical variables that can cause platelet activation. The aim of this study was to assess the effect of such variables that are present when samples are taken (different anticoagulants, incubation temperature, and storage conditions) to select those which enable to reach optimal range of measured plasma concentrations of the two stable thromboxane A₂ metabolites, that is, thromboxane B₂ (TxB₂) and 11-dehydrothromboxane B₂ (11-dTxB₂).
For the purpose of this study, whole blood samples obtained from 20 volunteers were screened for TxB₂ and 11-dTxB₂ concentrations using commercial EIA kits (Cayman Chemicals™; Neogen™) in relation to the effect of different anticoagulants, using different incubation temperatures and storage conditions.
Trisodium citrate has been shown not to be affecting the TxB₂ and 11-dTxB₂ concentrations compared with the values measured in the serum. Incubation of the samples for 1 h at 37 °C and freezing at -20 °C or -80 °C give the most suitable concentration range of both thromboxanes in the used EIA measurement.
This study describes the setup of such pre-analytical phase conditions that enable the screening of platelet function in terms of the plasma concentrations of TxB₂ and 11-dTxB₂ in selected EIA measurement.
血小板功能检测常常受到不同的预分析变量的影响,这些变量可能导致血小板活化。本研究旨在评估在采集样本时存在的这些变量(不同的抗凝剂、孵育温度和储存条件)对两种稳定血栓烷 A₂代谢物(即血栓烷 B₂(TxB₂)和 11-去氢血栓烷 B₂(11-dTxB₂)的血浆浓度测量值的影响,以便选择能达到最佳测量范围的条件。
为了进行这项研究,我们从 20 名志愿者中采集全血样本,使用商用 EIA 试剂盒(Cayman Chemicals™;Neogen™)来检测 TxB₂ 和 11-dTxB₂的浓度,同时研究不同抗凝剂、不同孵育温度和储存条件的影响。
与血清中测量的值相比,三钠枸橼酸盐对 TxB₂ 和 11-dTxB₂浓度没有影响。在 37°C 下孵育 1 小时并在-20°C 或-80°C 下冷冻,可获得最适合两种血栓烷在所用 EIA 测量中的浓度范围。
本研究描述了这种预分析阶段条件的设置,这些条件可以在选定的 EIA 测量中筛选血小板功能,评估 TxB₂ 和 11-dTxB₂的血浆浓度。