Dipartimento di Scienze Fisiche, Università degli Studi di Napoli Federico II, Italy.
J Environ Radioact. 2013 Jan;115:114-7. doi: 10.1016/j.jenvrad.2012.07.016. Epub 2012 Aug 19.
A survey of gamma exposure in dwellings of Campania region, southern Italy has been performed using Thermo Luminescent Dosimeters (TLD). In each dwelling TLDs were exposed for six months in the room where the inhabitant spent most of their time, generally the bedroom or living room. The arithmetic mean was found to be 264 ± 111 nGy/h, after the subtraction of the cosmic contribution. The effects of building materials and geographic location were also examined. Using UNSCEAR model, the annual effective dose due to indoor gamma radiation was evaluated and it was found to be 1.3 mSv/y, that is higher than Italian national average of 0.4 mSv/y.
对意大利南部坎帕尼亚地区居民住宅中的γ辐射进行了调查,使用了热释光剂量计(TLD)。在每个住宅中,TLD 在居民大部分时间居住的房间(通常是卧室或客厅)中暴露了六个月。在扣除宇宙辐射贡献后,发现算术平均值为 264 ± 111 nGy/h。还检查了建筑材料和地理位置的影响。使用 UNSCEAR 模型评估了室内γ辐射的年有效剂量,发现为 1.3 mSv/y,高于意大利全国平均水平 0.4 mSv/y。