应用 TLD、水模体和简化模型评估 Ga-67 核素检查患者的有效剂量。

Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model.

机构信息

Graduate Institute of Radiological Science, Central Taiwan University of Science and Technology, Takun, Taichung 40609, Taiwan.

出版信息

J Radiat Res. 2012 Nov 1;53(6):989-98. doi: 10.1093/jrr/rrs050. Epub 2012 Aug 21.

Abstract

This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even though gamma camera scanning took only minutes to complete the clinical examination. For effective simulation of the cumulated effective dose for a patient undergoing examination, 150 TLDs were placed inside the water phantom for 6 days to monitor the gamma ray dose from the distributed Ga-67 citrate solution. The inserted TLDs represented internal organs, and the effective dose was calculated according to data in the ICRP-60 report. The water phantom was designed to model the body of a healthy human weighing 70 kg, and the water that was mixed with Ga-67 citrate solution was slowly replaced with fresh feed water to yield the required biological half life of the phantom. After continuously feeding in fresh water throughout the 6 days of TLD exposure, the TLDs were analyzed to determine the effective doses from the various biological half lives of the phantom. The derived effective dose of 185 MBq Ga-67 citrate solution for male/female (M/F) was 10.7/12.2, 10.7/12.0, 8.7/9.9 and 6.0/6.8 mSv, of biological half lives of 6.0, 4.5, 3.0 and 1.5 days, respectively. Although these experimental results correlated well with earlier empirical studies, they were lower than most calculated values. The cumulated uncertainty in the effective dose was 12.5-19.4%, which was acceptable in terms of both TLD counting statistic and reproducibility.

摘要

本研究通过应用热释光剂量计(TLD)技术和国产水模体,评估了 Ga-67 柠檬酸核医学检查中患者的有效剂量。尽管伽马相机扫描只需几分钟即可完成临床检查,但体内残留的 Ga-67 放射性核素不可避免地会产生可测量的内部剂量。为了有效模拟接受检查的患者的累积有效剂量,将 150 个 TLD 置于水模体内部,以监测分布的 Ga-67 柠檬酸溶液产生的伽马射线剂量。插入的 TLD 代表内部器官,根据 ICRP-60 报告中的数据计算有效剂量。水模体旨在模拟体重 70kg 的健康人体,混合有 Ga-67 柠檬酸溶液的水被缓慢用新鲜饲料水替代,以产生所需的模体生物学半衰期。在整个 6 天的 TLD 暴露过程中连续输入新鲜水后,分析 TLD 以确定各种模体生物学半衰期的有效剂量。从 6.0、4.5、3.0 和 1.5 天的生物学半衰期得出,男性/女性(M/F)185MBq Ga-67 柠檬酸溶液的有效剂量分别为 10.7/12.2、10.7/12.0、8.7/9.9 和 6.0/6.8mSv。虽然这些实验结果与早期的经验研究吻合较好,但比大多数计算值低。有效剂量的累积不确定度为 12.5%-19.4%,在 TLD 计数统计和可重复性方面都是可以接受的。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/988a/3483851/f055fa04d052/rrs05001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验