Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom.
J Cataract Refract Surg. 2012 Oct;38(10):1796-801. doi: 10.1016/j.jcrs.2012.06.046. Epub 2012 Aug 21.
To evaluate visual and refractive outcomes in amblyopic patients who had bilateral implantation of a multifocal intraocular lens (IOL) with a surface-embedded near section.
Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom.
Comparative case series.
Anisometropic amblyopic patients having bilateral implantation of Lentis Mplus multifocal IOLs were examined for distance and near visual acuities, contrast sensitivity, defocus curves, extent of crowding, reading speed, stereoacuity, and Quality of Vision (QoV) questionnaire scores preoperatively and at 3-month intervals during 12 months. A +3.00 diopter (D) reading addition IOL was used in all eyes.
Twenty-eight eyes (14 patients) (mean age 59.4 years) were included. In the nonamblyopic eye, the mean uncorrected distance visual acuity (UDVA) was 0.16 logMAR ± 0.17 (SD), the mean corrected distance visual acuity (CDVA) was 0.02 ± 0.07 logMAR, and the mean near acuity was M 0.5 (Jaeger [J] 2 = logRAD 0.1) or better. In the amblyopic eye, the means were 0.30 ± 0.14 logMAR, 0.21 ± 0.11 logMAR, and M 0.8 (J4 = logRAD 0.3) or better, respectively. Bilateral reading speeds (mean 137.73 ± 28.7 words per minute [wpm]) surpassed unilateral nonamblyopic eye speeds (mean 130.6 ± 29.4 wpm). The mean QoV scores improved from 7.78 ± 10.23 preoperatively to 1.92 ± 5.21 at 12 months. No glare or halos were reported; 1 patient had mild starburst symptoms at 1 year. Patients rated distance and near vision as excellent.
Anisometropic amblyopic patients may benefit from bilateral implantation of the multifocal IOL; no unwanted side effects were detected.
评估双侧植入具有表面嵌入式近节段的多焦点人工晶状体(IOL)的弱视患者的视力和屈光结果。
英国北爱尔兰贝尔法斯特大教堂眼科诊所。
对比病例系列。
对双侧植入 Lentis Mplus 多焦点 IOL 的屈光不正性弱视患者进行距离和近视力、对比敏感度、散焦曲线、拥挤程度、阅读速度、立体视锐度和视觉质量(QoV)问卷评分检查。所有眼睛均使用+3.00 屈光度(D)阅读附加 IOL。
28 只眼(14 例患者)(平均年龄 59.4 岁)纳入研究。在非弱视眼中,平均未矫正远视力(UDVA)为 0.16 logMAR±0.17(SD),平均矫正远视力(CDVA)为 0.02±0.07 logMAR,平均近视力为 M 0.5(Jager [J] 2= logRAD 0.1)或更好。在弱视眼中,平均值分别为 0.30±0.14 logMAR、0.21±0.11 logMAR 和 M 0.8(J4=logRAD 0.3)或更好。双侧阅读速度(平均 137.73±28.7 个单词/分钟[wpm])超过单侧非弱视眼速度(平均 130.6±29.4 wpm)。平均 QoV 评分从术前的 7.78±10.23 提高到 12 个月时的 1.92±5.21。没有报告眩光或晕影;1 例患者在 1 年后出现轻度星爆症状。患者对远、近视力评价均为优秀。
屈光不正性弱视患者可能从双侧多焦点 IOL 植入中获益,未发现不良副作用。