Naito Y
Department of Otolaryngology, Okayama University Medical School.
Nihon Jibiinkoka Gakkai Kaiho. 1990 Dec;93(12):2021-7. doi: 10.3950/jibiinkoka.93.2021.
Sclerosis of auditory ossicle was experimentally induced by fixation of the stapes, and its effect on the tympanic membrane vibration was examined using fresh 10 canine temporal bones by means of holographic interferometry. By changing the sound pressure (from 90 to 110dB) and the frequency (from 250Hz to 8kHz) in steps, vibration of the membrane was induced in a free field. At each frequency, the vibration of the membrane was photographed by the time averaged method using He-Ne laser. A small hole was created in the tympanic bulla and the stapes was fixed with an adhesive (Alon Alpha), followed by closure of the hole. Before stapes fixation, the posterior part of the membrane showed a simple vibration pattern, forming cocentric interference circles at frequencies from 250Hz to 2kHz. At 3kHz, segmental vibration began to be noted, and complex segmental vibration was seen at frequencies 4.5 and 6kHz. The vibration after stapes fixation became simpler at frequencies over 3kHz, accompanied by decrease in the number of segmental vibrations. Vibration amplitude in the posterior part of the membrane decreased from 250Hz to 3kHz, while it increased at frequencies over 4kHz. In the anterior part of the membrane, the amplitude decreased at frequencies under 2kHz, remained unchanged at 3kHz and increased at frequencies over 4kHz after stapes fixation. In the tip of the manubrium mallei, the amplitude decreased at frequencies under 3kHz and increased at frequencies over 4kHz. Thus, a shift of peak vibration to high sound region was observed after stapes fixation at every part of tympanic membrane.(ABSTRACT TRUNCATED AT 250 WORDS)
通过固定镫骨,实验性诱导听小骨硬化,并使用10个新鲜犬颞骨,借助全息干涉测量法研究其对鼓膜振动的影响。通过逐步改变声压(从90分贝到110分贝)和频率(从250赫兹到8千赫兹),在自由声场中诱导鼓膜振动。在每个频率下,使用氦氖激光通过时间平均法拍摄鼓膜的振动。在鼓泡上开一个小孔,用粘合剂(Alon Alpha)固定镫骨,然后封闭小孔。在镫骨固定前,鼓膜后部呈现简单的振动模式,在250赫兹到2千赫兹的频率下形成同心干涉圈。在3千赫兹时,开始出现节段性振动,在4.5千赫兹和6千赫兹的频率下可见复杂的节段性振动。镫骨固定后,在3千赫兹以上的频率下振动变得更简单,节段性振动的数量减少。鼓膜后部的振动幅度在250赫兹到3千赫兹之间减小,而在4千赫兹以上的频率下增大。在鼓膜前部,镫骨固定后,在2千赫兹以下的频率下幅度减小,在3千赫兹时保持不变,在4千赫兹以上的频率下增大。在锤骨柄尖端,在3千赫兹以下的频率下幅度减小,在4千赫兹以上的频率下增大。因此,镫骨固定后,在鼓膜的每个部位都观察到振动峰值向高声区的偏移。(摘要截断于250字)