Suppr超能文献

日本乳腺细针穿刺细胞学诊断准确性:日本临床细胞学学会乳腺细针穿刺细胞学准确性工作组报告。

Diagnostic accuracy of fine-needle aspiration cytology of the breast in Japan: report from the Working Group on the Accuracy of Breast Fine-Needle Aspiration Cytology of the Japanese Society of Clinical Cytology.

机构信息

Department of Pathology, Kurume University School of Medicine/Kurume University Medical Center, Kurume, Japan.

出版信息

Oncol Rep. 2012 Nov;28(5):1606-12. doi: 10.3892/or.2012.2014. Epub 2012 Sep 3.

Abstract

The Working Group of the Japanese Society of Clinical Cytology was assembled to assess the current status of breast cytology in Japan by conducting a large-scale survey regarding the accuracy of fine-needle aspiration biopsy (FNAB) in Japan. We collected data and investigated the status of breast cytological diagnosis at 12 different cooperating facilities in Japan, and re-evaluated their false-negative and false-positive cases. Among 30,535 individuals who underwent a breast cytological examination, analyses were conducted on 10,890 individuals (35.7%) in whom cytological diagnoses were confirmed by histology. Among these patients, the cytological diagnosis had an inadequate rate of 17.7%, an indeterminate rate of 7.8%, a positive predictive value of 'malignancy suspected' cells of 92.4%, an absolute sensitivity of 76.7%, a complete sensitivity of 96.7%, a specificity of 84.3%, a positive predictive value of 'malignant' cells of 99.5%, a false-negative value of 3.31%, a false-positive value of 0.25% and an accuracy rate of 88.0%. Subsequently, 297 false-negative and 23 false-positive cases were re-evaluated and several factors were characterized (i.e. histological type, tumor size and misread points). This survey collected data from a large number of cases for breast FNAB. Based on our survey, the accuracy of FNAB in Japan was relatively high compared with the goal of assessment of diagnostic accuracy. However, there were some false-negative and false-positive cases. Improvements in accuracy resulting from the learning points in the present study will lead to more useful and reliable diagnostic tools in clinical practice.

摘要

日本临床细胞学会工作组通过对日本细针穿刺活检(FNAB)的准确性进行大规模调查,评估了日本的乳腺细胞学现状。我们收集了数据,并调查了日本 12 家合作机构的乳腺细胞学诊断现状,重新评估了它们的假阴性和假阳性病例。在接受乳腺细胞学检查的 30535 人中,对 10890 名(35.7%)细胞学诊断通过组织学证实的患者进行了分析。在这些患者中,细胞学诊断的不充分率为 17.7%,不明确率为 7.8%,可疑恶性细胞的阳性预测值为 92.4%,绝对敏感性为 76.7%,完全敏感性为 96.7%,特异性为 84.3%,恶性细胞的阳性预测值为 99.5%,假阴性率为 3.31%,假阳性率为 0.25%,准确率为 88.0%。随后,对 297 例假阴性和 23 例假阳性病例进行了重新评估,并对一些因素进行了特征描述(即组织学类型、肿瘤大小和误读点)。该调查从大量的乳腺 FNAB 病例中收集了数据。基于我们的调查,与诊断准确性评估目标相比,日本 FNAB 的准确性相对较高。然而,仍存在一些假阴性和假阳性病例。本研究的学习点可提高准确性,为临床实践提供更有用、更可靠的诊断工具。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验