Suppr超能文献

兔眼滤过术后测量房水流出通道模型的建立

A model to measure fluid outflow in rabbit capsules post glaucoma implant surgery.

机构信息

Centre for Eye Research Australia, University of Melbourne, Royal Victorian Eye and Ear Hospital, Melbourne, Australia.

出版信息

Invest Ophthalmol Vis Sci. 2012 Oct 5;53(11):6914-9. doi: 10.1167/iovs.12-10438.

Abstract

PURPOSE

Prior models of glaucoma filtration surgery assess bleb morphology, which does not always reflect function. Our aim is to establish a model that directly measures tissue hydraulic conductivity of postsurgical outflow in rabbit bleb capsules following experimental glaucoma filtration surgery.

METHODS

Nine rabbits underwent insertion of a single-plate pediatric Molteno implant into the anterior chamber of their left eye. Right eyes were used as controls. The rabbits were then allocated to one of two groups. Group one had outflow measurements performed at 1 week after surgery (n = 5), and group two had measurements performed at 4 weeks (n = 4). Measurements were performed by cannulating the drainage tube ostium in situ with a needle attached to a pressure transducer and a fluid column at 15 mm Hg. The drop in the fluid column was measured every minute for 5 minutes. For the control eyes (n = 6), the anterior chamber of the unoperated fellow eye was cannulated. Animals were euthanized with the implant and its surrounding capsule dissected and fixed in 4% paraformaldehyde, and embedded in paraffin before 6-μm sections were cut for histologic staining.

RESULTS

By 7 days after surgery, tube outflow was 0.117 ± 0.036 μL/min/mm Hg at 15 mm Hg (mean ± SEM), whereas at 28 days, it was 0.009 ± 0.003 μL/min/mm Hg. Control eyes had an outflow of 0.136 ± 0.007 μL/min/mm Hg (P = 0.004, one-way ANOVA). Hematoxylin and eosin staining demonstrated a thinner and looser arrangement of collagenous tissue in the capsules at 1 week compared with that at 4 weeks, which had thicker and more densely arranged collagen.

CONCLUSIONS

We describe a new model to directly measure hydraulic conductivity in a rabbit glaucoma surgery implant model. The principal physiologic endpoint of glaucoma surgery can be reliably quantified and consistently measured with this model. At 28 days post glaucoma filtration surgery, a rabbit bleb capsule has significantly reduced tissue hydraulic conductivity, in line with loss of implant outflow facility, and increased thickness and density of fibrous encapsulation.

摘要

目的

先前的青光眼滤过手术模型评估了滤过泡形态,但其并不总是反映功能。我们的目的是建立一种模型,该模型可直接测量实验性青光眼滤过手术后兔眼滤过泡囊内术后流出组织的水力传导系数。

方法

9 只兔子将单板式儿科 Molteno 植入物插入左眼前房。右眼作为对照。然后,将兔子分为两组。一组在手术后 1 周进行流出量测量(n = 5),另一组在手术后 4 周进行测量(n = 4)。通过将带有压力换能器和 15 毫米汞柱高的液柱的针头插入引流管口,原位进行测量。每分钟测量液柱下降 5 分钟。对于对照眼(n = 6),未手术对侧眼的前房被插管。在植入物及其周围囊被解剖并固定在 4%多聚甲醛中,然后在切成 6μm 切片进行组织学染色之前,将其嵌入石蜡中,处死动物。

结果

手术后 7 天,在 15 毫米汞柱下,管流出量为 0.117 ± 0.036 μL/min/mm Hg(平均值 ± SEM),而在 28 天时为 0.009 ± 0.003 μL/min/mm Hg。对照眼的流出量为 0.136 ± 0.007 μL/min/mm Hg(P = 0.004,单因素方差分析)。苏木精和伊红染色显示,与 4 周时相比,术后 1 周时囊内胶原组织排列更薄、更疏松,而 4 周时胶原更厚、排列更紧密。

结论

我们描述了一种新的模型,用于直接测量兔青光眼手术植入物模型中的水力传导系数。该模型可可靠地量化和一致地测量青光眼手术的主要生理终点。在青光眼滤过手术后 28 天,兔眼滤过泡囊内组织水力传导系数显著降低,与植入物流出道效能丧失一致,并且纤维包裹物的厚度和密度增加。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验