Suppr超能文献

两种磁可调节青光眼植入物原型在兔眼的比较。

Comparison of two prototypes of a magnetically adjustable glaucoma implant in rabbits.

机构信息

Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany.

Institute for Pathology, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany.

出版信息

PLoS One. 2019 Apr 11;14(4):e0215316. doi: 10.1371/journal.pone.0215316. eCollection 2019.

Abstract

Glaucoma drainage devices are used in surgical glaucoma therapy. Success of controlling the intraocular pressure is limited due to fibrous implant encapsulation and fibrin coating on the implant which lead to drainage obstructions. An innovative implant with a magnetically adjustable valve was developed. The valve opening of the implant should eliminate inflammatory products from the outflow area and affect fibrous tissue formation to achieve a sufficient long-term aqueous humour outflow. Lifting of this valve should disturb cell adhesion by exerting mechanical forces. Before testing this hypothesis, the flow characteristics of glaucoma drainage devices, especially the outflow resistance by regular IOP, should be considered in a pilot study, as they are important in preventing too low postoperative intraocular pressure known as ocular hypotony. Therefore, two prototypes of the innovative implant differing in their valve area design were examined regarding their flow characteristics in a limited animal experiment lasting two weeks. Ten healthy New Zealand White rabbits were divided into two groups (A & B) with different implanted prototypes. Daily, tonometry and direct ophthalmoscopy were performed to assess the intraocular pressure and the inflammatory reaction of the eye. After two weeks, the rabbits were euthanised to evaluate the initially histological inflammatory reaction to the implant. In group A, one case of hypotony emerged. When considering the entire observation period, a highly statistically significant difference between the intraocular pressure in the operated eye and that in the control eye was detected in group A (p < 0.0001) in contrast to group B (p = 0.0063). The postoperative inflammatory signs decreased within two weeks. Histologically, a typical but low level foreign body reaction with macrophages and lymphocytes as well as mild to moderate fibrosis was seen after the short experimental period. Based on our tonometric results, prototype B seems to be the system of choice for further research assessing its long-term function and biocompatibility.

摘要

青光眼引流装置用于外科青光眼治疗。由于植入物上的纤维状植入物包封和纤维蛋白涂层,导致引流阻塞,因此控制眼内压的成功率有限。开发了一种具有可调节磁阀的创新型植入物。该植入物的阀开口应从流出区消除炎症产物,并影响纤维组织形成,以实现足够的长期房水流出。提起此阀应通过施加机械力来干扰细胞黏附。在测试该假说之前,应在初步研究中考虑青光眼引流装置的流动特性,特别是通过常规眼压的流出阻力,因为它们在防止已知的术后眼压过低(称为眼球压低)方面很重要。因此,在为期两周的有限动物实验中,检查了两种在阀区设计上不同的创新型植入物原型的流动特性。将 10 只健康的新西兰白兔分为两组(A 和 B),每组植入不同的植入物原型。每天进行眼压测量和直接检眼镜检查,以评估眼内压和眼部炎症反应。两周后,对兔子进行安乐死以评估植入物最初的组织学炎症反应。在 A 组中,出现了一例眼压过低。在整个观察期内,A 组的手术眼和对照眼之间的眼内压差异具有高度统计学意义(p <0.0001),而 B 组的差异无统计学意义(p = 0.0063)。术后炎症迹象在两周内减少。组织学上,在短的实验期后,可见典型但低度的异物反应,伴有巨噬细胞和淋巴细胞以及轻度至中度纤维化。基于我们的眼压结果,原型 B 似乎是进一步研究其长期功能和生物相容性的首选系统。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a83e/6459522/b2f96f7613cd/pone.0215316.g001.jpg