Abstract

In this work, quantitative analysis of intact proteins using ion mobility spectrometry (IMS) is introduced. For this purpose a pneumatically assisted electrospray ionization source with a new design was constructed. Liquid and nebulizer gas flow rates were optimized to achieve the highest response. The pneumatically assisted electrospray-IMS was used for quantitative analysis of insulin, bovine serum albumin (BSA) and human serum albumin (HSA). The analysis of proteins demonstrated that sensitivity of the pneumatically assisted electrospray-IMS is two to three times higher than that of conventional electrospray ionization (ESI) coupled to IMS. The linear dynamic ranges for insulin, BSA and HSA were found to be 1-75, 5-100 and 2-100 μg mL(-1) with detection limits of 0.3, 1 and 0.6 μg mL(-1), respectively. The relative standard deviations (RSD) for five replicate measurements of insulin, BSA, and HSA at 25 μg mL(-1) were recorded as 3, 4 and 1.5%, respectively. The proposed method can be considered as an alternative way for quantitative protein analysis.

摘要

在这项工作中,引入了使用离子淌度谱(IMS)对完整蛋白质进行定量分析的方法。为此,构建了一种具有全新设计的气动辅助电喷雾电离源,并对其进行了优化以获得最高的响应。气动辅助电喷雾-IMS 被用于胰岛素、牛血清白蛋白(BSA)和人血清白蛋白(HSA)的定量分析。对蛋白质的分析表明,气动辅助电喷雾-IMS 的灵敏度比传统的与 IMS 耦合的电喷雾电离(ESI)高两到三倍。胰岛素、BSA 和 HSA 的线性动态范围分别为 1-75、5-100 和 2-100 μg mL(-1),检测限分别为 0.3、1 和 0.6 μg mL(-1)。在 25 μg mL(-1)时,胰岛素、BSA 和 HSA 的五个重复测量的相对标准偏差(RSD)分别记录为 3%、4%和 1.5%。该方法可以被视为定量蛋白质分析的一种替代方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验