Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran.
Anal Chim Acta. 2012 Oct 9;746:98-106. doi: 10.1016/j.aca.2012.08.024. Epub 2012 Aug 23.
A modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) and 3-(4-methoxybenzylideneamino)-2-thioxothiazolodin-4-one as a new synthesized Schiff base was constructed for the simultaneous determination of trace amounts of Hg(II) and Pb(II) by square wave anodic stripping voltammetry. The modified electrode showed an excellent selectivity and stability for Hg(II) and Pb(II) determinations and for accelerated electron transfer between the electrode and the analytes. The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as pH, deposition potential and deposition time were optimized for the purpose of determination of traces of metal ions at pH 3.0. Under optimal conditions the limits of detection, based on three times the background noise, were 9.0×10(-4) and 6.0×10(-4) μmol L(-1) for Hg(II) and Pb(II) with a 90 s preconcentration, respectively. In addition, the modified electrode displayed a good reproducibility and selectivity, making it suitable for the simultaneous determination of Hg(II) and Pb(II) in real samples such as sea water, waste water, tobacco, marine and human teeth samples.
一种基于多壁碳纳米管(MWCNTs)和 3-(4-甲氧基苯亚甲基氨基)-2-硫代噻唑啉-4-酮的新型合成希夫碱修饰碳糊电极,用于通过方波阳极溶出伏安法同时测定痕量 Hg(II) 和 Pb(II)。修饰电极对 Hg(II) 和 Pb(II) 的测定具有优异的选择性和稳定性,并且促进了电极和分析物之间的电子转移。研究了修饰电极的电化学性质和应用。优化了 pH、沉积电位和沉积时间等操作参数,以在 pH 3.0 下测定痕量金属离子。在最佳条件下,基于背景噪声的三倍,Hg(II) 和 Pb(II) 的检出限分别为 9.0×10(-4) 和 6.0×10(-4) μmol L(-1),预富集时间为 90 s。此外,修饰电极显示出良好的重现性和选择性,使其适用于海水中、废水中、烟草、海洋和人牙样品等实际样品中 Hg(II) 和 Pb(II) 的同时测定。