• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Heterogeneous delivery of cardioplegic solution in the absence of coronary artery disease.

作者信息

Aldea G S, Austin R E, Flynn A E, Coggins D L, Husseini W, Hoffman J I

机构信息

Cardiovascular Research Institute, University of California, San Francisco 94143.

出版信息

J Thorac Cardiovasc Surg. 1990 Feb;99(2):345-53.

PMID:2299874
Abstract

The prevention of intraoperative myocardial damage with cardioplegic solution depends in large measure on the completeness of its delivery. We created a model to study the regional flow distribution of cardioplegic solutions in nondiseased, diastolically arrested, maximally vasodilated canine hearts. Global and regional myocardial flows were measured at different perfusion pressures in hearts perfused either with blood cardioplegic solution (n = 8) or oxygenated crystalloid cardioplegic solution (n = 2). As coronary perfusion decreased, flow in all layers fell significantly (p less than 0.001). This fall was most dramatic in the subendocardium (p less than 0.05). With both types of cardioplegic solutions, the relationship between pressure and flow was nonlinear: At low coronary perfusion pressures, a given change in pressure resulted in a smaller change in flow than at higher perfusion pressures. In addition, we found that in all dogs and at all pressures there was profound variability in the delivery of cardioplegic solution to different small regions of the left ventricular free wall. At a perfusion pressure of 40 mm Hg, the extremes of regional flow differed on average by 203%. This heterogeneity increased significantly with decreasing perfusion pressures. At the lowest perfusion pressure measured (20 mm Hg), the extremes of regional flow differed on average by 365%. These findings emphasize the importance of coronary pressure on the delivery of cardioplegic solution. At low perfusion pressures, not only is mean flow reduced, but a greater number of regions receive limited amounts of cardioplegic solution. These observations may explain the patchy nature of subendocardial damage seen with inadequate myocardial protection.

摘要

相似文献

1
Heterogeneous delivery of cardioplegic solution in the absence of coronary artery disease.
J Thorac Cardiovasc Surg. 1990 Feb;99(2):345-53.
2
Myocardial protection in the failing heart: II. Effect of pulsatile cardioplegic perfusion under simulated left ventricular restoration.衰竭心脏的心肌保护:II. 模拟左心室恢复下搏动性心脏停搏液灌注的效果
J Thorac Cardiovasc Surg. 2006 Oct;132(4):884-90. doi: 10.1016/j.jtcvs.2006.04.048.
3
Studies of retrograde cardioplegia. I. Capillary blood flow distribution to myocardium supplied by open and occluded arteries.
J Thorac Cardiovasc Surg. 1989 Apr;97(4):605-12.
4
Distribution of cardioplegic solution infused antegradely and retrogradely in normal canine hearts.顺行和逆行灌注心脏停搏液在正常犬心脏中的分布。
J Thorac Cardiovasc Surg. 1989 Dec;98(6):1066-76.
5
Physical and mechanical effects of cardioplegic injection on flow distribution and myocardial damage in hearts with normal coronary arteries.心脏停搏液注射对正常冠状动脉心脏血流分布及心肌损伤的物理和机械效应。
J Thorac Cardiovasc Surg. 1989 Jun;97(6):870-7.
6
Efficacy of oxygenated University of Wisconsin solution containing endothelin-A receptor antagonist in twenty-four-hour heart preservation.含内皮素 - A受体拮抗剂的氧合威斯康星大学溶液在心脏二十四小时保存中的疗效
J Heart Lung Transplant. 1996 May;15(5):475-84.
7
Biventricular distribution of cold blood cardioplegic solution administered by different retrograde techniques.
J Thorac Cardiovasc Surg. 1991 Oct;102(4):631-7; discussion 637-8.
8
Studies of retrograde cardioplegia. II. Advantages of antegrade/retrograde cardioplegia to optimize distribution in jeopardized myocardium.逆行性心脏停搏的研究。II. 顺行性/逆行性心脏停搏在优化濒危心肌中分布的优势。
J Thorac Cardiovasc Surg. 1989 Apr;97(4):613-22.
9
Myocardial protection in the failing heart: I. Effect of cardioplegia and the beating state under simulated left ventricular restoration.衰竭心脏中的心肌保护:I. 模拟左心室恢复下心停搏和跳动状态的影响
J Thorac Cardiovasc Surg. 2006 Oct;132(4):875-83. doi: 10.1016/j.jtcvs.2006.03.067.
10
[Cardioprotective effects of cariporide as an adjunct in different cardioplegic solutions: an experiment with rabbits].[卡里波罗德作为不同心脏停搏液辅助药物的心脏保护作用:一项家兔实验]
Zhonghua Yi Xue Za Zhi. 2007 Sep 4;87(33):2320-3.