Batt M, Avril G, Gagliardi J M, Guzman R, Guidoin R, Boas N, Daune B, Hassen-Khodja R, Le Bas P
Department of Surgery, Hôpital Annexe-République, Centre Hospitalier Universitaire de Nice, France.
Can J Surg. 1990 Feb;33(1):61-5.
To evaluate patency, limb salvage rates and complications associated with the use of human umbilical vein as an arterial substitute, the authors carried out a retrospective review of 52 femorodistal bypasses performed over 9 years using human umbilical vein. Indications for operation included acute ischemia, rest pain and nonhealing ulceration or gangrene. There were 28 early occlusions, which resulted in a 1-month primary patency rate of 46% and a secondary patency rate of 52%. The primary and secondary patency rates at 1 year were 18% and 19% respectively. The mean limb salvage rate at 1 month was 57% and at 1 year 34%. Three aneurysms occurred (two anastomotic, one graft). Factors found to have a significant effect on patency rates were indication for operation and state of distal runoff. Infection occurred in 6% of grafts and led to amputation in every case. These disappointing results have caused the authors to discontinue use of human umbilical vein as an arterial substitute.