Suppr超能文献

高频机械通气对 C57BL/6J 和 BALB/c 成年小鼠呼吸系统力学的影响不同。

High frequency mechanical ventilation affects respiratory system mechanics differently in C57BL/6J and BALB/c adult mice.

机构信息

Georgetown University School of Medicine, 3900 Reservoir Rd, NW Washington, DC 20057-1481, United States.

出版信息

Respir Physiol Neurobiol. 2013 Jan 15;185(2):472-6. doi: 10.1016/j.resp.2012.09.012. Epub 2012 Sep 28.

Abstract

We tested the hypothesis that high frequency ventilation affects respiratory system mechanical functions in C57BL/6J and BALB/c mice. We measured respiratory mechanics by the forced oscillation technique over 1h in anesthetized, intubated, ventilated BALB/c and C57BL/6J male mice. We did not detect any change in airway resistance, Rn, tissue damping, G, tissue elastance, H and hysteresivity, eta in BALB/c mice during 1h of ventilation at 150 or at 450 breaths/min; nor did we find a difference between BALB/c mice ventilated at 150 breaths/min compared with 450 breaths/min. Among C57BL/6J mice, except for H, all parameters remained unchanged over 1h of ventilation in mice ventilated at 150 breaths/min. However, after 10 and 30 min of ventilation at 450 breaths/min, Rn, and respiratory system compliance were lower, and eta was higher, than their starting value. We conclude that high frequency mechanical ventilation affects respiratory system mechanics differently in C57BL/6J and BALB/c adult mice.

摘要

我们测试了高频通气是否会影响 C57BL/6J 和 BALB/c 小鼠的呼吸系统力学功能这一假说。我们通过强迫振荡技术在麻醉、插管和通气的 BALB/c 和 C57BL/6J 雄性小鼠中测量了 1 小时的呼吸力学。在 150 或 450 次/分钟通气 1 小时期间,我们未在 BALB/c 小鼠中检测到气道阻力 Rn、组织阻尼 G、组织弹性 H 和滞后性 eta 的任何变化;在 150 次/分钟通气的 BALB/c 小鼠与 450 次/分钟通气的 BALB/c 小鼠之间也未发现差异。在 C57BL/6J 小鼠中,除了 H 之外,所有参数在 150 次/分钟通气的小鼠中通气 1 小时内均保持不变。然而,在 450 次/分钟通气 10 和 30 分钟后,Rn 和呼吸系统顺应性降低,eta 高于起始值。我们得出结论,高频机械通气对 C57BL/6J 和 BALB/c 成年小鼠的呼吸系统力学有不同的影响。

相似文献

1
High frequency mechanical ventilation affects respiratory system mechanics differently in C57BL/6J and BALB/c adult mice.
Respir Physiol Neurobiol. 2013 Jan 15;185(2):472-6. doi: 10.1016/j.resp.2012.09.012. Epub 2012 Sep 28.
2
Protective mechanical ventilation does not exacerbate lung function impairment or lung inflammation following influenza A infection.
J Appl Physiol (1985). 2009 Nov;107(5):1472-8. doi: 10.1152/japplphysiol.00393.2009. Epub 2009 Sep 10.
3
Lung volume recruitment maneuvers and respiratory system mechanics in mechanically ventilated mice.
Respir Physiol Neurobiol. 2009 Dec 31;169(3):243-51. doi: 10.1016/j.resp.2009.09.012. Epub 2009 Sep 27.
4
Impact of supplemental oxygen in mechanically ventilated adult and infant mice.
Respir Physiol Neurobiol. 2009 Jan 1;165(1):61-6. doi: 10.1016/j.resp.2008.10.006. Epub 2008 Oct 17.
5
Measurement of changes in respiratory mechanics during partial liquid ventilation using jet pulses.
Crit Care Med. 2003 May;31(5):1435-41. doi: 10.1097/01.CCM.0000063041.94690.76.
6
Relationship between dynamic respiratory mechanics and disease heterogeneity in sheep lavage injury.
Crit Care Med. 2007 Mar;35(3):870-8. doi: 10.1097/01.CCM.0000257331.42485.94.
7
Unrestrained plethysmography is an unreliable measure of airway responsiveness in BALB/c and C57BL/6 mice.
J Appl Physiol (1985). 2004 Jul;97(1):286-92. doi: 10.1152/japplphysiol.00821.2003. Epub 2004 Mar 19.
8
Age-dependent changes of airway and lung parenchyma in C57BL/6J mice.
J Appl Physiol (1985). 2007 Jan;102(1):200-6. doi: 10.1152/japplphysiol.00400.2006. Epub 2006 Aug 31.
9
High tidal volume ventilation is not deleterious in infant rats exposed to severe hemorrhage.
J Trauma. 2010 Oct;69(4):E24-31. doi: 10.1097/TA.0b013e3181d7503c.
10
Different contributions from lungs and chest wall to respiratory mechanics in mice, rats, and rabbits.
J Appl Physiol (1985). 2019 Jul 1;127(1):198-204. doi: 10.1152/japplphysiol.00048.2019. Epub 2019 May 30.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验