Southworth S R, Hartwig R H
Medical College of Ohio.
J Hand Surg Br. 1990 Feb;15(1):111-2. doi: 10.1016/0266-7681_90_90063-a.
Fracture of an acupuncture needle resulted in a foreign body within the carpal tunnel of a patient who then developed median neuropathy. The needle fragment was recovered from within the median nerve during carpal tunnel release, with rapid post-operative relief of symptoms. Development of peripheral neuropathy is a potential complication of acupuncture.