Suppr超能文献

尿 pH 值试纸法与 pH 计法检测结果不一致:对甲氨蝶呤给药方案的影响。

Discordance between urine pH measured by dipstick and pH meter: implications for methotrexate administration protocols.

机构信息

Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, USA.

出版信息

Clin Biochem. 2013 Jan;46(1-2):152-4. doi: 10.1016/j.clinbiochem.2012.10.018. Epub 2012 Oct 24.

Abstract

OBJECTIVES

To minimize toxicity of high-dose methotrexate (MTX) therapy, urinary alkalinization with frequent monitoring of urine pH is required. Urine pH is usually assessed by fast and convenient dipstick methods. When urine color interferes with dipstick measurement, as occurs in patients receiving MTX, alternative methods such as pH meters are used. Nursing staff caring for patients on high-dose MTX reported that urine pH results from dipstick and pH analyzers were often clinically discordant. As a result urine pH by dipstick and pH meter were compared in patients on high-dose MTX therapy and patients with normal-colored urine samples.

DESIGN AND METHODS

We measured urine pH by dipstick and pH meter in 116 urine samples from 4 patients receiving high-dose MTX therapy, and in 50 normal-colored urine samples from 50 patients not on MTX therapy.

RESULTS

In patients on MTX therapy the mean (±standard deviation) bias between dipstick and pH meter urine pH was 0.7±0.4, compared to 0.4±0.3 in patients not on MTX. For patients on MTX clinical concordance between dipstick and pH meter urine results was poor around a clinical cut-off of pH 8.0. Of the 92 samples with a meter urine pH≤8.0, 72 had a discordant value by dipstick (pH>8).

CONCLUSIONS

Urine pH readings by dipstick and pH meter are not equivalent, and the bias between them is exacerbated in patients on MTX. Institutions with high-dose MTX therapy protocols should not alternate between dipstick and pH meter urine pH monitoring.

摘要

目的

为了将大剂量甲氨蝶呤(MTX)治疗的毒性降到最低,需要频繁监测尿液 pH 值,并对尿液进行碱化处理。尿液 pH 值通常通过快速便捷的尿试纸法进行评估。然而,当尿液颜色会干扰尿试纸检测时(例如接受 MTX 治疗的患者),就需要使用 pH 计等替代方法。护理接受大剂量 MTX 治疗的患者的医护人员报告称,尿试纸和 pH 计的尿液 pH 值结果往往存在临床差异。因此,研究人员比较了接受大剂量 MTX 治疗的患者和尿液颜色正常的患者的尿试纸和 pH 计测量的尿液 pH 值。

设计和方法

研究人员测量了 4 名接受大剂量 MTX 治疗的患者的 116 份尿液样本和 50 名未接受 MTX 治疗的患者的 50 份正常颜色尿液样本的尿试纸和 pH 计的尿液 pH 值。

结果

接受 MTX 治疗的患者中,尿试纸和 pH 计测量的尿液 pH 值之间的平均(±标准差)偏差为 0.7±0.4,而未接受 MTX 治疗的患者为 0.4±0.3。对于接受 MTX 治疗的患者,在临床 pH 临界值 8.0 附近,尿试纸和 pH 计测量的尿液结果之间的临床一致性较差。在 pH 计测量的尿液 pH 值≤8.0 的 92 份样本中,有 72 份样本的尿试纸结果(pH>8)存在差异。

结论

尿试纸和 pH 计测量的尿液 pH 值并不等效,在接受 MTX 治疗的患者中,两者之间的偏差更大。使用大剂量 MTX 治疗方案的机构不应该交替使用尿试纸和 pH 计监测尿液 pH 值。