Abstract

Concentrations of endogenous cortisol were examined in 34 kidney-transplant recipients by improved "high-performance" liquid chromatography. Ten recipients were treated with prednisolone and azathioprine, the others with prednisolone and cyclosporine. Peripheral serum samples were collected just before transplantation, daily for two weeks after the transplant, weekly until discharge for about two months, and then monthly or occasionally. Mean (+/- SD) cortisol concentrations, initially 145 +/- 87 micrograms/L, decreased immediately to 5.93 +/- 5.11 micrograms/L after transplant, remained at almost these same values for two months, and then swiftly increased to 51 +/- 59 micrograms/L by 1000 days. Cortisol concentrations within the period characterized by a cumulative dose of prednisolone at 300-700 mg were correlated significantly with the presence or absence of acute allograft rejection; patients with cortisol greater than 4 micrograms/L had a higher risk of rejection. The majority of stable patients showed cortisol concentrations between 1 and 4 micrograms/L throughout the cumulative prednisolone period characterized above. Concentrations less than 1 microgram/L after high-dose administration of methylprednisolone were accompanied by severe lung infection. We conclude that suppressed concentrations of endogenous cortisol, as assessed by highly specific HPLC, might provide a basis for predicting the therapeutic efficacy and adverse effects of prednisolone.

摘要

采用改良的“高效”液相色谱法检测了34例肾移植受者体内内源性皮质醇的浓度。10例受者接受泼尼松龙和硫唑嘌呤治疗,其余受者接受泼尼松龙和环孢素治疗。在移植前、移植后两周内每天、移植后约两个月内每周直至出院、然后每月或偶尔采集外周血样本。皮质醇平均(±标准差)浓度最初为145±87微克/升,移植后立即降至5.93±5.11微克/升,在两个月内几乎保持在这些相同水平,然后到1000天时迅速升至51±59微克/升。在泼尼松龙累积剂量为300 - 700毫克的时间段内,皮质醇浓度与急性移植排斥反应的发生与否显著相关;皮质醇大于4微克/升的患者排斥风险更高。在上述泼尼松龙累积期内,大多数病情稳定的患者皮质醇浓度在1至4微克/升之间。大剂量甲基泼尼松龙给药后浓度低于1微克/升的患者伴有严重肺部感染。我们得出结论,通过高特异性高效液相色谱法评估的内源性皮质醇浓度降低,可能为预测泼尼松龙的治疗效果和不良反应提供依据。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验