Stimulation of the pudendal nerve or the anal sphincter could provide therapeutic options for fecal incontinence with little involvement of other organs. The goal of this project was to assess the effects of pudendal nerve and anal sphincter stimulation on bladder and anal pressures.
Ten virgin female Sprague Dawley rats were randomly allocated to control (n = 2), perianal stimulation (n = 4), and pudendal nerve stimulation (n = 4) groups. A monopolar electrode was hooked to the pudendal nerve or placed on the anal sphincter. Aballoon catheter was inserted into the anus to measure anal pressure, and a catheter was inserted into the bladder via the urethra to measure bladder pressure. Bladder and anal pressures were measured with different electrical stimulation parameters and different timing of electrical stimulation relative to spontaneous anal sphincter contractions.
Increasing stimulation current had the most dramatic effect on both anal and bladder pressures. An immediate increase in anal pressure was observed when stimulating either the anal sphincter or the pudendal nerve at stimulation values of 1 mA or 2 mA. No increase in anal pressure was observed for lower current values. Bladder pressure increased at high current during anal sphincter stimulation, but not as much as during pudendal nerve stimulation. Increased bladder pressure during anal sphincter stimulation was due to contraction of the abdominal muscles.
Electrical stimulation caused an increase in anal pressures with bladder involvement only at high current. These initial results suggest that electrical stimulation can increase anal sphincter pressure, enhancing continence control.
刺激阴部神经或肛门括约肌可为大便失禁提供治疗选择,而对其他器官的影响较小。本项目的目的是评估阴部神经和肛门括约肌刺激对膀胱和肛门压力的影响。
将 10 只雌性 SD 大鼠随机分配至对照组(n = 2)、肛周刺激组(n = 4)和阴部神经刺激组(n = 4)。将单极电极连接到阴部神经或放置在肛门括约肌上。将球囊导管插入肛门以测量肛门压力,将导管通过尿道插入膀胱以测量膀胱压力。用不同的电刺激参数和不同的电刺激与自发性肛门括约肌收缩的时间关系来测量膀胱和肛门压力。
增加刺激电流对肛门和膀胱压力都有最显著的影响。当刺激电流为 1 mA 或 2 mA 时,刺激肛门括约肌或阴部神经时,肛门压力立即增加。较低的电流值不会引起肛门压力增加。在肛门括约肌刺激时,高电流下膀胱压力增加,但不如阴部神经刺激时增加得多。在肛门括约肌刺激时增加的膀胱压力是由于腹肌收缩所致。
电刺激在高电流时会引起肛门压力增加,并伴有膀胱参与。这些初步结果表明,电刺激可以增加肛门括约肌压力,增强控制排便的能力。