Suppr超能文献

用膜电极直接检测酸碱性和 pH 值。

Direct detection of acidity, alkalinity, and pH with membrane electrodes.

机构信息

Department of Inorganic, Analytical and Applied Chemistry, University of Geneva, Switzerland.

出版信息

Anal Chem. 2012 Dec 4;84(23):10165-9. doi: 10.1021/ac302868u. Epub 2012 Nov 13.

Abstract

An electrochemical sensing protocol based on supported liquid ion-selective membranes for the direct detection of total alkalinity of a sample that contains a weak base such as Tris (pK(a) = 8.2) is presented here for the first time. Alkalinity is determined by imposing a defined flux of hydrogen ions from the membrane to the sample with an applied current. The transition time at which the base species at the membrane-sample interface depletes owing to diffusion limitation is related to sample alkalinity in this chronopotentiometric detection mode. The same membrane is shown to detect pH (by zero current potentiometry) and acidity and alkalinity (by chronopotentiometry at different current polarity). This principle may become a welcome tool for the in situ determination of these characteristics in complex samples such as natural waters.

摘要

本文首次提出了一种基于支撑液离子选择性膜的电化学传感方案,用于直接检测含有弱碱(如 Tris,pK(a) = 8.2)的样品的总碱度。通过在施加电流的情况下从膜向样品中强制输送一定量的氢离子来确定碱度。在这种计时电位检测模式下,由于扩散限制,膜-样品界面上的碱基物质耗尽的过渡时间与样品碱度有关。该膜还可用于检测 pH 值(通过零电流电位法)以及在不同电流极性下的酸度和碱度(通过计时电位法)。该原理可能成为原位测定天然水等复杂样品中这些特性的一种受欢迎的工具。