Suppr超能文献

肾皮质-髓质区分:应用时间飞跃标记反转脉冲稳态自由进动(time-SLIP)序列的非对比增强磁共振成像技术的评估。

Corticomedullary differentiation of the kidney: evaluation with noncontrast-enhanced steady-state free precession (SSFP) MRI with time-spatial labeling inversion pulse (time-SLIP).

机构信息

Department of Radiology, Kawasaki Medical School, Kurashiki, Japan.

出版信息

J Magn Reson Imaging. 2013 May;37(5):1178-81. doi: 10.1002/jmri.23909. Epub 2012 Nov 13.

Abstract

PURPOSE

To assess whether noncontrast-enhanced steady-state free precession (SSFP) magnetic resonance imaging (MRI) with time-spatial labeling inversion pulse (Time-SLIP) can improve the visibility of corticomedullary differentiation of the normal kidney.

MATERIALS AND METHODS

A series of noncontrast-enhanced SSFP MRI with Time-SLIP were performed in 20 patients by using various inversion times (TIs); 500-1800 msec in increments of 100 msec. In-phase (IP) and opposed-phase (OP) MR images were also obtained. The signal intensity (SI) of the renal cortex and medulla was measured to calculate corticomedullary contrast ratio (SI of cortex/medulla). Additionally, the visibility of corticomedullary differentiation was visually categorized using a four-point scale.

RESULTS

In SSFP with Time-SLIP, corticomedullary contrast ratio was highest with TI of 1200 msec in eight subjects (40%), followed by 1100 msec in seven (35%) and 1000 msec in three (15%). The corticomedullary contrast ratio in SSFP with optimal Time-SLIP (4.93 ± 1.25) was significantly higher (P < 0.001) than those of IP (1.46 ± 0.12) and OP (1.43 ± 0.14). The visibility of corticomedullary differentiation was significantly better (P < 0.001) in SSFP images with Time-SLIP (averaged grade = 4.0) than in IP images (averaged grade = 2.63) and OP images (averaged grade = 2.05).

CONCLUSION

SSFP MRI with Time-SLIP can improve the visibility of renal corticomedullary differentiation without using contrast agents.

摘要

目的

评估时间空间标记反转脉冲(Time-SLIP)非对比增强稳态自由进动(SSFP)磁共振成像(MRI)是否可以提高正常肾脏皮质髓质分化的可视性。

材料与方法

对 20 例患者进行了一系列非对比增强 SSFP MRI 检查,采用 Time-SLIP,反转时间(TI)分别为 500-1800 毫秒,增量为 100 毫秒。同时还获得了同相位(IP)和反相位(OP)MR 图像。测量肾皮质和髓质的信号强度(SI),计算皮质髓质对比比(皮质/髓质 SI)。此外,还使用 4 分制对皮质髓质分化的可视性进行了分类。

结果

在 Time-SLIP 的 SSFP 中,8 例(40%)患者的 TI 为 1200 毫秒时皮质髓质对比比最高,其次是 7 例(35%)患者的 TI 为 1100 毫秒,3 例(15%)患者的 TI 为 1000 毫秒。最佳 Time-SLIP 的 SSFP 皮质髓质对比比(4.93±1.25)明显高于 IP(1.46±0.12)和 OP(1.43±0.14)(P<0.001)。Time-SLIP 的 SSFP 图像的皮质髓质分化的可视性明显优于 IP 图像(平均等级=2.63)和 OP 图像(平均等级=2.05)(P<0.001)。

结论

Time-SLIP 非对比增强 SSFP MRI 可以在不使用造影剂的情况下提高肾脏皮质髓质分化的可视性。