Department of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki 036-8562, Japan.
Eur Spine J. 2013 Jan;22(1):205-10. doi: 10.1007/s00586-012-2573-8. Epub 2012 Nov 21.
Ossification of the posterior longitudinal ligament (OPLL) of the cervical spine has been classified into four types by lateral plain radiographs, but the reliability of the classification and of the diagnosis of either cervical OPLL or cervical spondylotic myelopathy (CSM) was unknown. We investigated the interobserver and intraobserver reliability of the classification and diagnosis for OPLL by radiographs and computed tomography (CT) images.
A total of 16 observers classified each patient's images into five groups; OPLL continuous, segmental, mixed, circumscribed type, or CSM. To evaluate interobserver reliability, the observers first classified only radiograph images, and next both radiographs and CT images. On another day they followed the same procedure to evaluate intraobserver reliability. We also evaluated interobserver and intraobserver reliability of the diagnosis of either cervical OPLL or CSM.
Interobserver reliability of the classification with radiographs only showed moderate agreement, but interobserver reliability with both radiographs and CT images showed substantial agreement. Intraobserver of reliability the classification was also improved by additional CT images. Interobserver reliability of the diagnosis with both radiographs and CT images was almost similar to with radiographs only. Intraobserver reliability of the diagnosis was improved by additional CT images.
This study suggested that the reliability of the classification and diagnosis for cervical OPLL was improved by additional CT images. We propose that diagnostic criteria for OPLL include both radiographs and CT images.
颈椎后纵韧带骨化症(OPLL)在侧位平片上可分为四型,但该分型的可靠性以及颈椎 OPLL 或颈椎脊髓病(CSM)的诊断准确性尚不清楚。我们通过 X 线平片和 CT 图像来研究 OPLL 分型和诊断的观察者间和观察者内可靠性。
共 16 名观察者将每位患者的图像分为 5 组:连续型、节段型、混合型、局限型或 CSM。为了评估观察者间的可靠性,观察者首先仅对 X 线平片进行分类,然后同时对 X 线平片和 CT 图像进行分类。在另一天,他们按照相同的程序评估观察者内的可靠性。我们还评估了对颈椎 OPLL 或 CSM 的诊断的观察者间和观察者内可靠性。
仅使用 X 线平片进行分类的观察者间可靠性显示为中度一致,但同时使用 X 线平片和 CT 图像进行分类的观察者间可靠性显示为高度一致。额外的 CT 图像也提高了观察者内分类的可靠性。同时使用 X 线平片和 CT 图像的诊断的观察者间可靠性几乎与仅使用 X 线平片时相同。额外的 CT 图像提高了观察者内诊断的可靠性。
本研究表明,通过额外的 CT 图像可提高颈椎 OPLL 分型和诊断的可靠性。我们建议,OPLL 的诊断标准应包括 X 线平片和 CT 图像。