Van Beers B, Pringot J, Gigot J F, Dautrebande J, Mathurin P
Department of Radiology, St-Luc University Hospital, Brussels, Belgium.
Gastrointest Radiol. 1990 Spring;15(2):107-11. doi: 10.1007/BF01888750.
Nineteen patients with suspected hepatic neoplasms underwent dynamic computed tomography (CT) and computed tomographic porotography (CTP) in a preoperative setting. Nontumorous attenuation differences in the liver were observed in 8 patients (42%) with CTP and in 2 patients (10.5%) with dynamic CT (p less than 0.05). Although nontumorous attenuation differences are significantly more frequent with CTP than with dynamic CT, they are seldom a diagnostic problem because of their geographic pattern.
19例疑似肝脏肿瘤患者在术前接受了动态计算机断层扫描(CT)和计算机断层扫描门静脉造影(CTP)。CTP检查发现8例患者(42%)肝脏存在非肿瘤性衰减差异,动态CT检查发现2例患者(10.5%)存在该差异(p<0.05)。虽然CTP检查发现非肿瘤性衰减差异的频率显著高于动态CT,但由于其呈地图样分布,很少会造成诊断问题。