Magaña-Sandoval Fabian, Adhikari Rana X, Frolov Valera, Harms Jan, Lee Jacqueline, Sankar Shannon, Saulson Peter R, Smith Joshua R
Department of Physics, California State University Fullerton, Fullerton, California 92831, USA.
J Opt Soc Am A Opt Image Sci Vis. 2012 Aug 1;29(8):1722-7. doi: 10.1364/JOSAA.29.001722.
Optical loss from scattered light could limit the performance of quantum-noise filter cavities being considered for an upgrade to the Advanced Laser Interferometer Gravitational Wave Observatory (LIGO) gravitational-wave detectors. This paper describes imaging scatterometer measurements of the large-angle scattered light from two high-quality sample optics, a high reflector and a beamsplitter. These optics are each superpolished fused silica substrates with silica:tantala dielectric coatings. They represent the current state-of-the art optical technology for use in filter cavities. We present angle-resolved scatter values and integrate these to estimate the total scatter over the measured angles. We find that the total integrated light scattered into larger angles can be as small as 4 ppm.