Baratieri Carolina, Mattos Cláudia Trindade, Alves Matheus, Lau Thiago Chon Leon, Nojima Lincoln Issamu, de Souza Margareth Maria Gomes, Araujo Monica Tirre, Nojima Matilde da Cunha Gonçalves
Department of Orthodontics, Dental School, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
Braz Dent J. 2012;23(4):394-8. doi: 10.1590/s0103-64402012000400014.
The hypothesis tested in this study was that intraoral exposure of elastomeric chains alters their tensile strength. For such purpose, it was evaluated the in situ behavior of different elastomeric chains stretched for 3 weeks. Three kinds of elastomeric chains, Plastic chain (PC), Memory chain (MC) and Super slick chain (SSC), were randomly placed in 3 quadrants of 13 patient in a fixed distance of 16 mm and mean initial force of 180 g. Tensile testing was performed in an universal testing machine at different intervals: initial, 1 h, 24 h, 1 week, 2 weeks and 3 weeks. A two-way ANOVA test was performed to identify the influence of both material and time on the force decrease. A subsequent one-way ANOVAtest with the Tukey's post hoc test was used to identify statistically significant intragroup and intergroup remaining force (g and %) differences at 5% significance level. The effect of both the material and the time factors were significant. All groups showed significant force decrease after the 1-h period (23% for PC and 14% for MC and SSC). At the end of the 3-week period, the remaining force was 57% (96 g), 67% (129 g) and 71% (125 g) for PC, MC and SSC, respectively. In conclusion, intraoral exposure of elastomeric chains altered their tensile strength. In general, the greater force decrease occurred within the first hour. The remaining force of the enhanced chains measured at each time interval was greater than the conventional one (PC). After 3 weeks, only the enhanced chains maintained the force applied over 100 g.
本研究检验的假设是,口腔内暴露的弹性链体会改变其拉伸强度。为此,对拉伸3周的不同弹性链体的原位行为进行了评估。将三种弹性链体,即塑料链(PC)、记忆链(MC)和超顺滑链(SSC),以16毫米的固定间距和180克的平均初始力随机放置在13名患者的3个象限中。在万能试验机上于不同时间间隔进行拉伸测试:初始、1小时、24小时、1周、2周和3周。进行双向方差分析以确定材料和时间对力降低的影响。随后使用带有Tukey事后检验的单向方差分析来确定在5%显著性水平下组内和组间剩余力(克和%)的统计学显著差异。材料和时间因素的影响均具有显著性。所有组在1小时后均显示出显著的力降低(PC为23%,MC和SSC为14%)。在3周结束时,PC、MC和SSC的剩余力分别为57%(96克)、67%(129克)和71%(125克)。总之,弹性链体的口腔内暴露改变了其拉伸强度。一般来说,在最初一小时内力降低幅度更大。在每个时间间隔测量的增强链体的剩余力大于传统链体(PC)。3周后,只有增强链体保持了超过100克的施加力。