Suppr超能文献

弹性链的力衰减——系列研究。第二部分。

Force decay of elastomeric chain--a serial study. Part II.

作者信息

Lu T C, Wang W N, Tarng T H, Chen J W

机构信息

Department of Dentistry, Tri-Service General Hospital, Taipei, Taiwan, Republic of China.

出版信息

Am J Orthod Dentofacial Orthop. 1993 Oct;104(4):373-7. doi: 10.1016/S0889-5406(05)81336-8.

Abstract

This study was designed to evaluate the relaxation of elastomeric chain over time. The purposes were to compare the force decay curves of three variously stretched lengths, as well as to compare transparent and grey elastomeric chains. The elastomeric chains were fixed on a stainless steel framework that was submerged in 37 degrees C water bath for 6 weeks. The elastic forces of the chains were measured by a Dial-Type dynamometer, and recorded at the initial activation, first hour, eighth hour, twenty-fourth hour, third day, and then weekly to 6 weeks. The stretched length of the chains were decreased 0.5 mm per week. The results showed: (1) The sequence of stretch force at each time measurement of the Rocky Mountain clear energy chain was 40 mm > 35 mm > 30 mm. However, the percentage of remaining force was 40 mm < 35 mm < 30 mm. (2) The remaining force and the percentage of remaining force of the American Orthodontic short transparent chain were greater than the remaining force of the gray chain. (3) The remaining force and the percentage of remaining force of the Rocky Mountain clear chain with 40 mm stretch were greater than that of the American Orthodontic transparent and grey chains. (4) The effective force for canine retraction (184 gm) can be maintained by the Rocky Mountain energy chain with 40 mm, 35 mm, and 30 mm stretch for about 3 weeks, 1 week, and 3 days, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本研究旨在评估弹性链随时间的松弛情况。目的是比较三种不同拉伸长度的力衰减曲线,以及比较透明和灰色弹性链。弹性链固定在不锈钢框架上,该框架浸没在37摄氏度的水浴中6周。通过表盘式测力计测量链的弹力,并在初始激活时、第1小时、第8小时、第24小时、第3天进行记录,然后每周记录一次,直至6周。链的拉伸长度每周减少0.5毫米。结果显示:(1)落基山透明能量链每次测量时的拉伸力顺序为40毫米>35毫米>30毫米。然而,剩余力的百分比为40毫米<35毫米<30毫米。(2)美国正畸短透明链的剩余力和剩余力百分比大于灰色链的剩余力。(3)拉伸40毫米的落基山透明链的剩余力和剩余力百分比大于美国正畸透明链和灰色链。(4)对于犬齿后移的有效力(184克),拉伸40毫米、35毫米和30毫米的落基山能量链分别可维持约3周、1周和3天。(摘要截断于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验