Department of Rehabilitation for Movement Functions, Research Institute, National Rehabilitation Center for Persons with Disabilities, Saitama, Japan.
Spinal Cord. 2013 Apr;51(4):327-30. doi: 10.1038/sc.2012.145. Epub 2012 Dec 4.
Retrospective study at a rehabilitation center.
Patients with spinal cord injury, even if they are wheelchair users, sometimes suffer from fractures of the lower limb bones. As their bones are too weak to have surgery, and because a precise reduction is not required for restoration, such patients are often indicated for conservative treatment. This case series study investigated the use of a hinged, soft-plastic brace as a conservative approach to treating fractures of the lower extremities of patients with spinal cord injury.
National Rehabilitation Center, Japan.
Fifteen patients (male, n=10; female, n=5; average age, 52.7 years) with 19 fractures of the femur or the tibia who were treated with a newly-developed hinged, soft-plastic brace were studied. All of them used wheelchairs. We analyzed the time taken for fracture union and for wearing orthotics, degree of malalignment, femorotibial angle and side effects.
The fractures in this series were caused by relatively low-energy impact. The average time taken for fracture union was 80.1 (37-189) days, and the average amount of time spent wearing orthotics was 77.9 (42-197) days. On final X-ray imaging, the average femorotibial angle was 176.9° (s.d. ±8.90), and 15° of misalignment in the sagittal plane occurred in one patient.
A hinged, soft-plastic brace is a useful option as a conservative approach for treating fractures of the lower extremities in patients with spinal cord injury.
康复中心的回顾性研究。
脊髓损伤患者即使是轮椅使用者,有时也会出现下肢骨骨折。由于他们的骨骼太脆弱而无法进行手术,而且对于恢复来说不需要精确的复位,因此这些患者通常需要保守治疗。本病例系列研究调查了使用铰链式软塑料支具作为保守治疗方法来治疗脊髓损伤患者下肢骨折的情况。
日本国家康复中心。
研究了 15 名(男性 10 名,女性 5 名;平均年龄 52.7 岁)患有股骨或胫骨骨折的患者,他们使用了新开发的铰链式软塑料支具进行治疗。所有患者均使用轮椅。我们分析了骨折愈合和佩戴矫形器的时间、对线不良程度、股胫角和副作用。
本系列中的骨折是由相对低能量的撞击引起的。骨折愈合的平均时间为 80.1(37-189)天,佩戴矫形器的平均时间为 77.9(42-197)天。在最终的 X 射线成像上,平均股胫角为 176.9°(标准差±8.90),有 1 名患者在矢状面出现 15°的对线不良。
铰链式软塑料支具是治疗脊髓损伤患者下肢骨折的一种有用的保守治疗选择。