Suppr超能文献

[应用20兆赫超声评估地索奈德和地蒽酚局部给药对银屑病皮损的疗效]

[Evaluation of effect of local administration of desoximetasone and ditranol in psoriatic lesion byapplying 20 MHz ultrasound].

作者信息

Stojković Tatjana, Binić Ivana, Tiodorović Jelica

机构信息

Visoka medicinska skola strukovnih studija, Cuprija, Klinicki centar, Nis.

出版信息

Med Pregl. 2012 Sep-Oct;65(9-10):368-72. doi: 10.2298/mpns1210368s.

Abstract

INTRODUCTION

This prospective study was aimed at examining the modification of ultrasound characteristics of psoriatic plaques during desoximetasone and dithranol treatment.

MATERIAL AND METHODS

The examination included 50 patients with chronic plaque-type psoriasis to whom 0.25% desoximetasone and dithranol was applied on the psoriatic lesions in the period of 21 days. The changes were measured before and every 7 days after the beginning of therapy by the combined application of A- and B-mode echosonography. RESULTS. At the beginning of the examination, the average values of the enter echo were 0.67 +/- 0.53 mm; hypoehogen shadow 0.30 +/- 0.11 mm, and dermis thickness 3.03 +/- 1.05 mm. On the first check up, the average values of the enter echo were 0.45 +/- 0.29 mm; hypoechogen shadow 0.23 +/- 0.08 mm and dermis thickness 2.65 +/- 0.97 mm. On the second check up, the average values of the enter echo were 0.30 +/- 0.18 mm; hypoechogen shadow 0.21 +/- 0.18 mm, dermis thickness 2.18 +/- 0.82 mm. On the third check up, the average values of the enter echo were 0.24 +/- 0.17 mm; hypoechogen shadow 0.18 +/- 0.17 mm, and dermis thickness 1.8 +/- 0.69 mm. DISCUSSION. The evaluation of the ultrasonographic characteristics revealed a significant reduction in the values in the course of the examination. Statistically significant differences were found before, during, and at the end of the examination by recording the ultrasound parameters of the epidermis and dermis and by following their modification. CONCLUSION. Precise determination of ultrasound parameters of epidermis and dermis and the possibility of recording their modification in a shorter or longer time interval can be used for monitoring and assessment of therapy effect of a medication.

摘要

引言

本前瞻性研究旨在检测在使用去氧米松和地蒽酚治疗期间银屑病斑块超声特征的变化。

材料与方法

该检查纳入50例慢性斑块型银屑病患者,在21天内对其银屑病皮损应用0.25%去氧米松和地蒽酚。在治疗开始前以及开始后每7天,通过联合应用A模式和B模式超声检查来测量变化。结果:在检查开始时,表皮回声的平均值为0.67±0.53毫米;低回声阴影为0.30±0.11毫米,真皮厚度为3.03±1.05毫米。在第一次检查时,表皮回声的平均值为0.45±0.29毫米;低回声阴影为0.23±0.08毫米,真皮厚度为2.65±0.97毫米。在第二次检查时,表皮回声的平均值为0.30±0.18毫米;低回声阴影为0.21±0.18毫米,真皮厚度为2.18±0.82毫米。在第三次检查时,表皮回声的平均值为0.24±0.17毫米;低回声阴影为0.18±0.17毫米,真皮厚度为1.8±0.69毫米。讨论:超声特征评估显示在检查过程中各项数值显著降低。通过记录表皮和真皮的超声参数并跟踪其变化,发现在检查前、检查期间和检查结束时有统计学显著差异。结论:精确测定表皮和真皮的超声参数以及在较短或较长时间间隔内记录其变化的可能性可用于监测和评估药物的治疗效果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验