Tei Katsumasa, Ishida Kazunari, Matsumoto Tomoyuki, Kubo Seiji, Sasaki Hiroshi, Shibanuma Nao, Akisue Toshihiro, Nishida Kotaro, Kurosaka Masahiro, Kuroda Ryosuke
Department of Orthopaedic Surgery, Kobe Kaisei Hospital, Kobe City, Japan.
Orthopedics. 2012 Dec;35(12):e1711-5. doi: 10.3928/01477447-20121120-14.
Although 2-dimensional assessments using postoperative plain radiographs have been used after total knee arthroplasty (TKA) in previous studies, a strong possibility exists that deviation can occur when assessing 3-dimensional (3-D) objects. The purpose of this study was to test the hypothesis that novel 3-D image-matching software could accurately assess the positioning of implants and could be a useful tool in postoperative evaluation after TKA.Total knee arthroplasty was performed in 30 consecutive patients. Intraoperatively, the thickness of each bone cut was measured. Postoperatively, the thickness of each part of the bone cut was measured using Athena Knee (SoftCube Co, Ltd, Osaka, Japan) 3-D image-matching software. The results revealed no significant differences in the medial compartment and significant differences of approximately 1 mm in the lateral compartment. The difference was possibly caused by the remaining cartilage in the lateral compartment. Linear regression analysis revealed a statistically excellent correlation between intra- and postoperative values in all parts of the bone cuts. Although the 3-D image-matching software used in this study was originally developed for preoperative planning in TKA, it is considered accurate enough to assess the positioning of implants with respect to the bone after TKA.
尽管在以往的研究中,全膝关节置换术(TKA)后使用术后X线平片进行二维评估,但在评估三维(3-D)物体时很有可能出现偏差。本研究的目的是验证以下假设:新型三维图像匹配软件能够准确评估植入物的位置,并且可以成为TKA术后评估的有用工具。
连续30例患者接受了全膝关节置换术。术中测量了每处截骨的厚度。术后,使用Athena Knee(日本大阪SoftCube有限公司)三维图像匹配软件测量截骨各部分的厚度。结果显示,内侧间室无显著差异,外侧间室有大约1毫米的显著差异。这种差异可能是由外侧间室残留的软骨引起的。线性回归分析显示,截骨各部分的术中和术后测量值之间存在统计学上的高度相关性。尽管本研究中使用的三维图像匹配软件最初是为TKA术前规划开发的,但它被认为足以准确评估TKA术后植入物相对于骨骼的位置。