Branquinho Renata Tupinambá, Mosqueira Vanessa Carla Furtado, Kano Eunice Kazue, de Souza Jacqueline, Dorim Diego Dias Ramos, Saúde-Guimarães Dênia Antunes, de Lana Marta
1Programa de Pós-Graduação em Ciências Farmacêuticas (CiPharma), Escola de Farmácia, Universidade Federal de Ouro Preto - Rua Costa Sena 171, Centro, CEP: 35400-000, Ouro Preto, MG, Brazil.
J Chromatogr Sci. 2014 Jan;52(1):19-26. doi: 10.1093/chromsci/bms199. Epub 2012 Dec 17.
Simple and sensitive methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and ultraviolet (UV)-spectrophotometry were developed and compared to quantify lychnopholide (LYC) in poly-ε-caprolactone nanocapsules and to study its release kinetics. Both methods were validated concerning their specificity, linearity, limits of detection and quantification, precision, accuracy and stability. HPLC-DAD analyses were conducted using an RP C18 column, isocratic elution with a methanol-water (60:40 v/v) mobile phase at 0.8 mL/min flow rate and detection at 265 nm. The linear response (r(2) > 0.999) was obtained within a concentration range of 2-25 µg/mL using HPLC-DAD and 5-40 µg/mL using spectrophotometry. Intra-day and inter-day precision were obtained with low relative standard deviation values. The accuracy of the methods was within the range 98-101% for HPLC-DAD and from 96-100% for UV-spectrophotometry. Both methods were suitable to be applied for the determination of drug loading percentage (>96%) and encapsulation efficiency (>90%). Furthermore, the sensitivity of HPLC-DAD method allows studies of LYC release/dissolution in sink conditions. LYC presented 100% dissolution after 24 h, whereas only 60% of LYC was released from the nanocapsule dosage form, with no burst effect. The methods fulfilled all validation parameters evaluated for LYC quantification in the polymeric nanocapsules and have proven to be accurate, selective and sensitive in the previously mentioned applications.
开发了使用高效液相色谱 - 二极管阵列检测(HPLC - DAD)和紫外(UV)分光光度法的简单且灵敏的方法,并对其进行比较,以定量聚ε - 己内酯纳米胶囊中的石蒜醇酯(LYC)并研究其释放动力学。两种方法在特异性、线性、检测限和定量限、精密度、准确度和稳定性方面均经过验证。HPLC - DAD分析使用RP C18柱,以甲醇 - 水(60:40 v/v)为流动相进行等度洗脱,流速为0.8 mL/min,检测波长为265 nm。使用HPLC - DAD在2 - 25 µg/mL的浓度范围内获得线性响应(r(2) > 0.999),使用分光光度法在5 - 40 µg/mL的浓度范围内获得线性响应。日内和日间精密度的相对标准偏差值较低。HPLC - DAD方法的准确度在98 - 101%范围内,紫外分光光度法的准确度在96 - 100%范围内。两种方法均适用于测定载药率(>96%)和包封率(>90%)。此外,HPLC - DAD方法的灵敏度允许研究LYC在漏槽条件下的释放/溶解情况。LYC在24小时后呈现100%溶解,而纳米胶囊剂型中仅释放了60%的LYC,无突释效应。这些方法满足了对聚合物纳米胶囊中LYC定量评估的所有验证参数,并且在上述应用中已被证明是准确、选择性和灵敏的。