Suppr超能文献

推注注射对心脏骤停期间循环时间的影响。

The effect of bolus injection on circulation times during cardiac arrest.

作者信息

Emerman C L, Pinchak A C, Hancock D, Hagen J F

机构信息

Department of Emergency Medicine, Case Western Reserve University, Cleveland, OH.

出版信息

Am J Emerg Med. 1990 May;8(3):190-3. doi: 10.1016/0735-6757(90)90319-u.

Abstract

Previous investigations have shown that peripheral injection of medication during cardiac arrest leads to prolonged circulation times and low peak drug levels. Current Advanced Cardiac Life Support guidelines suggest that administering a bolus of flush solution after injection of medication may hasten drug delivery, but there is little evidence to support this. The purpose of this study is to investigate the effect of peripheral bolus injection on circulation times during cardiac arrest. Measurements of circulation times were made following injection of indocyanine green dye both with and without a bolus of 20 mL saline flush into a peripheral vein of mongrel dogs. There was no difference in systolic, diastolic, or coronary perfusion pressures during the injections with or without bolus injection. Similarly, there was no difference in end-tidal CO2 or in arterial-venous PO2, PCO2, or pH gradient. The circulation time without bolus injection was 77.7 +/- 42.7 seconds while circulation time with the saline flush was 48.3 +/- 20.9 seconds (P less than .001). Peak dye concentration without saline flush was 3.0 +/- 1.0 mg/L, and peak dye concentration with saline flush was 3.8 +/- 0.9 mg/L (P less than .001). We conclude that a bolus injection of 20 mL of saline enhances dye circulation times and peak levels during cardiac arrest in this animal model. The clinical application of this technique warrants further investigation.

摘要

先前的研究表明,在心脏骤停期间经外周注射药物会导致循环时间延长和药物峰值水平较低。当前的高级心脏生命支持指南建议,在注射药物后推注冲洗液可能会加速药物输送,但几乎没有证据支持这一点。本研究的目的是调查在心脏骤停期间外周推注对循环时间的影响。在杂种犬的外周静脉注射吲哚菁绿染料后,分别在推注20 mL生理盐水冲洗液和不推注的情况下测量循环时间。在推注或不推注的注射过程中,收缩压、舒张压或冠状动脉灌注压没有差异。同样,呼气末二氧化碳或动静脉氧分压、二氧化碳分压或pH梯度也没有差异。不推注时的循环时间为77.7±42.7秒,而推注生理盐水冲洗液时的循环时间为48.3±20.9秒(P<0.001)。不使用生理盐水冲洗时的染料峰值浓度为3.0±1.0 mg/L,使用生理盐水冲洗时的染料峰值浓度为3.8±0.9 mg/L(P<0.001)。我们得出结论,在该动物模型中,推注20 mL生理盐水可提高心脏骤停期间的染料循环时间和峰值水平。该技术的临床应用值得进一步研究。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验