Yan Fei, Li Jianhong, Xian Junfang, Wang Zhenchang, Mo Lingyan
Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Acta Radiol. 2013 Apr 1;54(3):292-8. doi: 10.1258/ar.2012.110596. Epub 2013 Jan 14.
There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND.
To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children.
HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND.
CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was <1.5 mm in 36 ears (66.7%). The CNC diameter ranged between 1.5 and 2.0 mm in seven ears (13.0%) and was >2.0 mm in 11 ears (20.4%). The IAC diameter was <3.0 mm in 25 ears (46.3%) and >3.0 mm in 29 ears (53.7%).
The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC.
聋儿人工耳蜗植入(CI)的需求频率日益增加,选择合适的候选者需要更详细的图像信息。耳蜗神经缺如(CND)是CI的禁忌症。磁共振成像(MRI)已被用于评估耳蜗神经的完整性。据报道,耳蜗神经管(CNC)和内耳道(IAC)的异常与CND有关。
将儿童高分辨率CT(HRCT)上的CNC表现、大小和IAC直径与MRI诊断的CND进行相关性分析。
回顾性研究35例感音神经性聋儿童的HRCT图像,这些儿童耳蜗正常,但MRI诊断为双侧或单侧CND。评估CNC和IAC的表现及大小,并与CND进行相关性分析。
54/70耳(77.1%)经MRI诊断为CND。32耳耳蜗神经缺如(59.3%),22耳耳蜗神经细小(40.7%)。36耳(66.7%)的CNC直径<1.5 mm。7耳(13.0%)的CNC直径在1.5至2.0 mm之间,11耳(20.4%)的CNC直径>2.0 mm。25耳(46.3%)的IAC直径<3.0 mm,29耳(53.7%)的IAC直径>3.0 mm。
CNC发育不全可能比IAC狭窄更能提示CND。