Suppr超能文献

3.0T腕部MRI的定性和定量评估:各向同性3D快速自旋回波、各向同性3D快速场回波与2D快速自旋回波之间的比较

Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo.

作者信息

Jung Jee Young, Yoon Young Cheol, Jung Jin Young, Choe Bong-Keun

机构信息

Department of Radiology, Chungang University Hospital, School of Medicine, Chungang University, Korea.

出版信息

Acta Radiol. 2013 Apr 1;54(3):284-91. doi: 10.1258/ar.2012.120475. Epub 2013 Jan 14.

Abstract

BACKGROUND

Isotropic three-dimensional (3D) magnetic resonance imaging (MRI) has been applied to various joints. However, comparison for image quality between isotropic 3D MRI and two-dimensional (2D) turbo spin echo (TSE) sequence of the wrist at a 3T MR system has not been investigated.

PURPOSE

To compare the image quality of isotropic 3D MRI including TSE intermediate-weighted (VISTA) sequence and fast field echo (FFE) sequence with 2D TSE intermediate-weighted sequence of the wrist joint at 3.0 T.

MATERIAL AND METHODS

MRI was performed in 10 wrists of 10 healthy volunteers with isotropic 3D sequences (VISTA and FFE) and 2D TSE intermediate-weighted sequences at 3.0 T. The signal-to-noise ratio (SNR) was obtained by imaging phantom and noise-only image. Contrast ratios (CRs) were calculated between fluid and cartilage, triangular fibrocartilage complex (TFCC), and the scapholunate ligament. Two radiologists independently assessed the visibility of TFCC, carpal ligaments, cartilage, tendons and nerves with a four-point grading scale. Statistical analysis to compare CRs (one way ANOVA with a Tukey test) and grades of visibility (Kruskal-Wallis test) between three sequences and those for inter-observer agreement (kappa analysis) were performed.

RESULTS

The SNR of 2D TSE (46.26) was higher than those of VISTA (23.34) and 3D FFE (19.41). CRs were superior in 2D TSE than VISTA (P = 0.02) for fluid-cartilage and in 2D TSE than 3D FFE (P < 0.01) for fluid-TFCC. The visibility was best in 2D TSE (P < 0.01) for TFCC and in VISTA (P = 0.01) for scapholunate ligament. The visibility was better in 2D TSE and 3D FFE (P = 0.04) for cartilage and in VISTA than 3D FFE (P < 0.01) for TFCC. The inter-observer agreement for the visibility of anatomic structures was moderate or substantial.

CONCLUSION

Image quality of 2D TSE was superior to isotropic 3D MR imaging for cartilage, and TFCC. 3D FFE has better visibility for cartilage than VISTA and VISTA has superior visibility for TFCC to 3D FFE and the visibility for scapholunate ligament was best on VISTA.

摘要

背景

各向同性三维(3D)磁共振成像(MRI)已应用于各种关节。然而,在3T MR系统中,尚未对腕关节的各向同性3D MRI与二维(2D)涡轮自旋回波(TSE)序列的图像质量进行比较。

目的

比较3.0T下腕关节的各向同性3D MRI(包括TSE中等加权(VISTA)序列和快速场回波(FFE)序列)与2D TSE中等加权序列的图像质量。

材料与方法

对10名健康志愿者的10个腕关节进行MRI检查,采用3.0T的各向同性3D序列(VISTA和FFE)和2D TSE中等加权序列。通过成像体模和仅含噪声的图像获得信噪比(SNR)。计算液体与软骨、三角纤维软骨复合体(TFCC)以及舟月韧带之间的对比率(CRs)。两名放射科医生使用四点分级量表独立评估TFCC、腕骨韧带、软骨、肌腱和神经的可视性。进行统计分析以比较三个序列之间的CRs(采用Tukey检验的单因素方差分析)和可视性等级(Kruskal-Wallis检验)以及观察者间一致性(kappa分析)。

结果

2D TSE的SNR(46.26)高于VISTA(23.34)和3D FFE(19.41)。在液体-软骨方面,2D TSE的CRs优于VISTA(P = 0.02);在液体-TFCC方面,2D TSE的CRs优于3D FFE(P < 0.01)。对于TFCC,2D TSE的可视性最佳(P < 0.01);对于舟月韧带,VISTA的可视性最佳(P = 0.01)。对于软骨,2D TSE和3D FFE的可视性更好(P = 0.04);对于TFCC,VISTA的可视性优于3D FFE(P < 0.01)。观察者间对解剖结构可视性的一致性为中等或较高。

结论

对于软骨和TFCC,2D TSE的图像质量优于各向同性3D MR成像。3D FFE对软骨的可视性优于VISTA,VISTA对TFCC的可视性优于3D FFE,且舟月韧带在VISTA上的可视性最佳。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验