Doheny Retina Institute, Doheny Eye Institute, Los Angeles, CA, USA.
Curr Eye Res. 2013 Feb;38(2):299-304. doi: 10.3109/02713683.2012.757625. Epub 2013 Feb 1.
The purpose of this study is to quantify the normal retinal thickness (RT) and retinal nerve fiber layer thickness (RNFLT), and to obtain cross-sectional area measurements of the main retinal artery and vein in the rabbit animal model using spectral domain optical coherence tomography (SD-OCT).
Fifteen eyes of 15 adult rabbits were used to obtain SD-OCT scans. RT, RNFLT and cross-sectional areas of the main retinal artery and vein were measured with a custom-made software grading tool (OCTOR) on selected B-scans at the edge of the optic nerve head and at 1, 2, 3 and 4 mm from the nerve. Statistical comparisons were made using the analysis of variance test with post hoc comparison.
In the nasal and temporal retina, the average RT and RNFLT decreased significantly with eccentricity from the optic disc. There was a statistically significant greater RT and RNFLT at the edge of the optic disc as compared with values at 1, 2, 3 and 4 mm from the disc edge (p < 0.01). Mean cross-sectional area of the primary retinal vein was significantly larger than the retinal artery (p < 0.01).
We have quantified the cross-sectional dimensions of RT, RNFLT and the major retinal vessels in the rabbit retina with SD-OCT. These findings are novel anatomic features of the rabbit retina, which should be considered in any studies using this animal model.
本研究旨在使用谱域光相干断层扫描(SD-OCT)定量测量兔动物模型的正常视网膜厚度(RT)和视网膜神经纤维层厚度(RNFLT),并获得主要视网膜动脉和静脉的横截面积测量值。
使用 15 只成年兔的 15 只眼获得 SD-OCT 扫描。使用定制的软件分级工具(OCTOR)在视神经头边缘和距神经 1、2、3 和 4mm 处的选定 B 扫描上测量 RT、RNFLT 和主要视网膜动脉和静脉的横截面积。使用方差分析检验进行统计比较,并进行事后比较。
在鼻侧和颞侧视网膜中,RT 和 RNFLT 随离视盘的偏心度显著降低。与距盘缘 1、2、3 和 4mm 处的数值相比,视盘边缘的 RT 和 RNFLT 有统计学意义上的显著增加(p<0.01)。初级视网膜静脉的平均横截面积明显大于视网膜动脉(p<0.01)。
我们使用 SD-OCT 对兔视网膜的 RT、RNFLT 和主要视网膜血管的横截面尺寸进行了量化。这些发现是兔视网膜的新解剖特征,在使用这种动物模型的任何研究中都应考虑到这些特征。