Dobecki Marek
Nofer Institute of Occupational Medicine, Łódź, Poland.
Med Pr. 2012;63(6):723-32.
This paper reviews the requirements for measurement methods of chemical agents in the air at workstations. European standards, which have a status of Polish standards, comprise some requirements and information on sampling strategy, measuring techniques, type of samplers, sampling pumps and methods of occupational exposure evaluation at a given technological process. Measurement methods, including air sampling and analytical procedure in a laboratory, should be appropriately validated before intended use. In the validation process, selected methods are tested and budget of uncertainty is set up. The validation procedure that should be implemented in the laboratory together with suitable statistical tools and major components of uncertainity to be taken into consideration, were presented in this paper. Methods of quality control, including sampling and laboratory analyses were discussed. Relative expanded uncertainty for each measurement expressed as a percentage, should not exceed the limit of values set depending on the type of occupational exposure (short-term or long-term) and the magnitude of exposure to chemical agents in the work environment.