Suppr超能文献

Viabahn用于股腘动脉支架内再狭窄

Viabahn for femoropopliteal in-stent restenosis.

作者信息

Al Shammeri Owayed, Bitar Fahad, Ghitelman Jaime, Soukas Peter A

机构信息

Medicine, Qassim University, PO Box 6655 Buraidah 51452, Saudi Arabia.

出版信息

Ann Saudi Med. 2012 Nov-Dec;32(6):572-82. doi: 10.5144/0256-4947.2012.575.

Abstract

BACKGROUND AND OBJECTIVES

In-stent restenosis in the femoropopliteal artery is common (20%-40%). Treatment of in-stent restenosis is challenged by poor patency rate. An ePTFE-covered stent-graft (Viabahn) is inert with a very small pore size that does not allow for significant tissue in-growth. Use of a Viabahn stent-graft may improve the patency rate in the treatment of in-stent restenosis.

DESIGN AND SETTING

A retrospective chart review of the use of Viabahn stent grafts implanted in patients with symptomatic femoropopliteal artery in-stent restenosis performed from January 2004 to December 2008.

PATIENTS AND METHODS

We measured the primary patency rate using duplex ultrasound at 1 year and 3 years. We also examined the rate of secondary patency, acute limb ischemia and amputation.

RESULTS

Twenty-seven cases with in-stent restenosis of the femoropopliteal artery treated by Viabahn stentgraft were identified. The average lesion length was 24.5 cm; 52% of the lesions were total occlusion and 37% had critical limb ischemia. The 1- and 3-year primary patency rates were 85.1% and 81.4%, respectively. The secondary patency rate was 96%. All recurrent in-stent restenoses were focal at the proximal and distal edges and none had stent fracture.

CONCLUSION

Our single center experience in a small number of patients showed a favorable patency of ePTFE-covered stent-graft for treatment of patients with in-stent restenosis in the femoropopliteal artery.

摘要

背景与目的

股腘动脉支架内再狭窄很常见(20%-40%)。支架内再狭窄的治疗面临着通畅率低的挑战。一种ePTFE覆膜支架移植物(Viabahn)具有惰性,孔径非常小,不允许大量组织向内生长。使用Viabahn支架移植物可能会提高支架内再狭窄治疗的通畅率。

设计与地点

对2004年1月至2008年12月期间为有症状的股腘动脉支架内再狭窄患者植入Viabahn支架移植物的情况进行回顾性图表分析。

患者与方法

我们使用双功超声在1年和3年时测量了主要通畅率。我们还检查了次要通畅率、急性肢体缺血和截肢率。

结果

共确定了27例接受Viabahn支架移植物治疗的股腘动脉支架内再狭窄病例。平均病变长度为24.5厘米;52%的病变为完全闭塞,37%的患者存在严重肢体缺血。1年和3年的主要通畅率分别为85.1%和81.4%。次要通畅率为96%。所有复发性支架内再狭窄均局限于近端和远端边缘,且均无支架断裂。

结论

我们单中心对少数患者的经验表明,ePTFE覆膜支架移植物在治疗股腘动脉支架内再狭窄患者方面具有良好的通畅性。