Pradeep Nishna, Sreekumar A V
Department of Prosthodontics, Kannur Dental College, Anjarakandy, Kerala, India.
J Contemp Dent Pract. 2012 Nov 1;13(6):838-41. doi: 10.5005/jp-journals-10024-1239.
Aim of this study was to assess the cytotoxicity of monomer. An in vitro study was designed to study the growth inhibitory effect of monomer (Stellon, Denture Material Improved, Type I, Class I, Dental Products of India Limited) on cells seeded in petri dishes and maintained in an incubator with 5% carbon dioxide at 37 °C. The growth of V79 cells (fibroblast cells) maintained in a culture medium to which monomer was added was studied for a period of 5 days. Results of this study pointed out that even at a concentration of 1 µl of monomer, the cell growth was significantly inhibited, when compared to the control group. The number of viable cells decreased dramatically whereas dead cells increased in the culture groups treated with the monomer. The cytotoxic effect was dose dependent. As the concentration increased from 1 to 10 µl there was a marked inhibition of cell growth and a corresponding increase in dead cell count. Results of this study proved beyond doubt that monomer is indeed cytotoxic even in very low concentrations. Thus, it becomes imperative to adopt every possible means to minimize residual monomer content in heat cured resins. Also precautions to minimize tissue contact should be taken while handling monomer by the dentist and dental personnel in the laboratory.
本研究的目的是评估单体的细胞毒性。设计了一项体外研究,以研究单体(Stellon,改良义齿材料,I型,I类,印度牙科产品有限公司)对接种在培养皿中并置于37°C、5%二氧化碳培养箱中的细胞的生长抑制作用。研究了添加单体的培养基中V79细胞(成纤维细胞)的生长情况,为期5天。本研究结果指出,与对照组相比,即使单体浓度为1微升,细胞生长也受到显著抑制。在用单体处理的培养组中,活细胞数量急剧减少,而死细胞数量增加。细胞毒性作用呈剂量依赖性。随着浓度从1微升增加到10微升,细胞生长受到明显抑制,死细胞数量相应增加。本研究结果毫无疑问地证明,即使在极低浓度下,单体确实具有细胞毒性。因此,必须采取一切可能的措施来尽量减少热固化树脂中的残留单体含量。此外,牙医和实验室中的牙科人员在处理单体时应采取预防措施,尽量减少与组织的接触。