Di Francescantonio Marina, Aguiar Thaiane Rodrigues, Arrais César Augusto Galvão, Cavalcanti Andrea Nóbrega, Davanzo Celso Ulysses, Giannini Marcelo
Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, BRAZIL.
Eur J Dent. 2013 Jan;7(1):81-5.
The purpose of this study was to evaluate the effects of the viscosities and curing modes on the degree of conversion (DC) of two resin cements.
Eight experimental groups were evaluated (n=5), according to the dual-cured resin cements (Nexus 2/Variolink II), viscosity (low and high) and evaluation time (5 minutes and 24 hours). The resin cements were applied to surface of a horizontal attenuated-total-reflectance unit and were polymerized either with self-cure (SC) or light exposure (XL3000/3M ESPE) for 40 seconds. Infrared spectra were obtained after 5 minutes and 24 hours (Nicolet 520 FT-IR/Thermo Scientific Inc.). DC was calculated according to changes in aliphatic-to-aromatic peak ratios pre- and post-curing. Data (%) were analyzed by 3-way repeated measure ANOVA (curing mode, viscosity and time interval) and Tukey's post-hoc test (P<.05).
The dual-polymerizing mode provided higher DC than auto-polymerization. The DC mean values increased for both resin cements after 24 hours. The low-viscosity resin cements from light-activated or self-cured groups exhibited higher DC than high viscosity version.
The DC of resin cements was higher for the low viscosity version, following the light-polymerization and when were tested after 24 hours.
本研究旨在评估两种树脂水门汀的黏度和固化方式对其固化转化率(DC)的影响。
根据双重固化树脂水门汀(Nexus 2/Variolink II)、黏度(低黏度和高黏度)以及评估时间(5分钟和24小时),对8个实验组(每组n = 5)进行评估。将树脂水门汀涂覆在水平衰减全反射装置的表面,通过自固化(SC)或光照(XL3000/3M ESPE)聚合40秒。在5分钟和24小时后获取红外光谱(Nicolet 520傅里叶变换红外光谱仪/赛默飞世尔科技公司)。根据固化前后脂肪族与芳香族峰比值的变化计算DC。数据(%)采用三因素重复测量方差分析(固化方式、黏度和时间间隔)和Tukey事后检验(P<0.05)进行分析。
双重聚合模式比自聚合提供更高的DC。24小时后,两种树脂水门汀的DC平均值均增加。光活化或自固化组的低黏度树脂水门汀比高黏度树脂水门汀表现出更高的DC。
低黏度树脂水门汀在光聚合后以及24小时后测试时,其DC更高。