Suppr超能文献

通过延长体外肺灌注的肺修复时间,是否有可能进一步改善肺移植的功能?

Is it possible to further improve the function of pulmonary grafts by extending the duration of lung reconditioning using ex vivo lung perfusion?

作者信息

Pierre L, Lindstedt S, Hlebowicz J, Ingemansson R

机构信息

Department of Cardiothoracic Surgery, Skåne University Hospital, Lund University, Lund, Sweden.

出版信息

Perfusion. 2013 Jul;28(4):322-7. doi: 10.1177/0267659113479424. Epub 2013 Feb 22.

Abstract

BACKGROUND

The method of ex vivo lung perfusion (EVLP) has been suggested as a reliable means of differentiating between "good" and "poor" pulmonary grafts in marginal donors as, when grafts identified as good by this method are transplanted, the results do not differ from those using lungs fulfilling standard criteria. The EVLP method is also thought to improve pulmonary grafts by reducing lung edema and eliminating lung atelectasis. In the present study, we investigated whether the pulmonary graft could be further improved by extending the duration of EVLP.

METHODS AND MATERIALS

Six Landrace pigs were used. The lungs were reconditioned and evaluated, using the EVLP method, as double lungs. After the initial evaluation, EVLP was continued for a further 90 minutes.

RESULTS

The arterial oxygen level (pO2) was 60.8 ± 4.8 kPa after the standard 60 minutes of EVLP and 67.1 ± 2.2 kPa after 150 minutes (p = 0.48). The pulmonary vascular resistance was 453 ± 78 dyne*s/cm(5) after 60, 90, 120 and 150 minutes of EVLP (p = 1.0). The pulmonary artery pressure was 17.8 ± 1.0 mmHg after 60, 90, 120, and 150 minutes of EVLP (p = 1.0) and the pulmonary artery flow was 3.5 ± 0.4 l/min after 60, 90, 120, and 150 minutes of EVLP (p = 1.0). The mean weight of the pulmonary grafts after harvesting was 574 ± 20 g at the beginning of EVLP 541 ± 24 g and, after 150 min of EVLP, 668 ± 33 (p = 0.011).

CONCLUSIONS

The blood gases and hemodynamic parameters in the pulmonary grafts did not improve as a result of the extra 90 minutes of EVLP. However, the weight of the pulmonary graft increased significantly with increasing duration of EVLP, indicating lung perfusion injury.

摘要

背景

体外肺灌注(EVLP)方法被认为是区分边缘供体中“优质”和“劣质”肺移植的可靠手段,因为当通过该方法鉴定为优质的移植肺进行移植时,其结果与使用符合标准标准的肺移植结果并无差异。EVLP方法还被认为可通过减轻肺水肿和消除肺不张来改善肺移植。在本研究中,我们调查了延长EVLP持续时间是否能进一步改善肺移植。

方法和材料

使用6头长白猪。采用EVLP方法将肺作为双肺进行再处理和评估。初始评估后,EVLP再持续90分钟。

结果

标准的60分钟EVLP后动脉血氧水平(pO2)为60.8±4.8kPa,150分钟后为67.1±2.2kPa(p = 0.48)。EVLP 60、90、120和150分钟后肺血管阻力为453±78达因·秒/厘米⁵(p = 1.0)。EVLP 60、90、120和150分钟后肺动脉压为17.8±1.0mmHg(p = 1.0),肺动脉流量为3.5±0.4升/分钟(p = 1.0)。收获后肺移植的平均重量在EVLP开始时为574±20克,EVLP 150分钟后为541±24克,之后为668±33克(p = 0.011)。

结论

额外90分钟的EVLP并未改善肺移植中的血气和血流动力学参数。然而,随着EVLP持续时间的增加,肺移植的重量显著增加,表明存在肺灌注损伤。