Palma Gámiz J L, Yuste Pescador P, Señor de Uría J, Gay I
Servicio de Cardiología, Hospital Ramón y Cajal, Madrid.
Arch Inst Cardiol Mex. 1990 Jan-Feb;60(1):39-44.
A study to evaluate late potentials (LP) was carried out in 50 patients diagnosed as suffering from coronary heart disease. All the patients were divided into two groups: Group A, was made of 25 patients in the acute period of myocardial infarction, and group B, was made of other 25 patients in the chronic phase, with more of 3 months of evolution from the acute event. Average age in group A was 54.2 years, and 58.1 years in group B. Twenty normal volunteer subjects (group C) were also studied as a reference group. All the subjects in the 3 groups were in normal sinus rhythm, and no one of them showed bundle branch block in the basal ECG. Analysis of the vector magnitude was made for each point of the averaged wave, as the result of the mean root square of the addition of bipolar leads X, Y and Z, using a LP-3000 Fidelity Medical Inc. equipment, with a four poles Butterworth filter. LP were detected in 32% of the patients in group A, and in 56% of the group B (p less than 0.001). No LP was observed in patients of the group C. Concerning the localization of myocardial infarction, maximum CPK value, or Lown's grade of ventricular arrhythmias observed in coronary care unit, or in the 3rd week Holter monitoring, did not show significant statistical correlationship with the presence of LP in group A.(ABSTRACT TRUNCATED AT 250 WORDS)
一项评估晚期电位(LP)的研究在50例被诊断患有冠心病的患者中进行。所有患者被分为两组:A组由25例处于心肌梗死急性期的患者组成,B组由另外25例处于慢性期的患者组成,自急性事件起病程超过3个月。A组平均年龄为54.2岁,B组为58.1岁。另外20名正常志愿者(C组)作为参照组进行研究。三组所有受试者均为正常窦性心律,且在基础心电图中均未显示束支传导阻滞。使用LP - 3000 Fidelity Medical Inc.设备及四极巴特沃斯滤波器,对平均波的每个点进行矢量大小分析,该分析结果为双极导联X、Y和Z相加后的均方根。A组32%的患者检测到LP,B组为56%(p小于0.001)。C组患者未观察到LP。关于心肌梗死的部位、在冠心病监护病房观察到的最高肌酸磷酸激酶值或室性心律失常的洛恩分级,或在第3周动态心电图监测中,均未显示与A组中LP的存在有显著统计学相关性。(摘要截断于250字)