Suppr超能文献

移植人心脏的三维左心室中层动力学

Three-dimensional left ventricular midwall dynamics in the transplanted human heart.

作者信息

Ingels N B, Daughters G T, Stinson E B, Alderman E L, Miller D C

机构信息

Research Institute, Palo Alto Medical Foundation, CA 94301.

出版信息

Circulation. 1990 Jun;81(6):1837-48. doi: 10.1161/01.cir.81.6.1837.

Abstract

To quantify the three-dimensional regional dynamics of the left ventricular (LV) midwall and the centroid and cross-sectional shape of the LV chamber in the transplanted human heart, 12 miniature radiopaque tantalum markers were implanted in the LV midwall of the donor heart at the time of cardiac transplantation in 15 patients. Stereo cineradiography in the late postoperative period (mean, 52 days after surgery) allowed computer-aided measurements of the three-dimensional coordinates of multiple sites in anterior, inferior, lateral, and septal LV regions at 16.7-msec intervals throughout the cardiac cycle. In awake, supine patients, from maximum to minimum LV volume, group mean translations of free wall markers ranged from 0.80 to 1.24 cm, directed toward the LV interior, whereas translations of septal wall markers were significantly less, 0.46 and 0.34 cm (p less than 0.01), directed away from the LV interior. A component of this translation along the septal-lateral axis was also significantly less (p less than 0.01) in the septum (0.19 and 0.20 cm) than in the free wall, where it ranged from 0.32 to 0.97 cm. The LV cross section was not circular, and anterior-inferior dimensions (7.18 +/- 0.66 and 6.13 +/- 0.79 cm, at maximum and minimum volumes, respectively) were significantly greater (p less than 0.01) than septal-lateral dimensions (5.78 +/- 0.65 and 5.12 +/- 0.48 cm), yielding an unchanging transverse elliptical LV eccentricity (0.58 +/- 0.13). The position of the LV center of volume did not change significantly from maximum to minimum volume in the direction of either the LV long axis or the anterior-inferior axis, but it did change significantly (0.55 +/- 0.23 cm, p less than 0.01) along the septal-lateral axis. We conclude 1) as viewed in a fixed external reference system, midwall sites in the interventricular septum of the transplanted human heart move paradoxically yet are relatively immobile compared with the three-dimensional dynamics of midwall sites in the LV free wall; 2) the transverse cross-sectional shape of the LV in the transplanted human heart is decidedly oval, with significantly greater anterior-posterior than septal-lateral dimensions at the time of maximum and minimum LV volumes; and 3) the center of volume in the transplanted human LV is remarkably stable in the directions of the LV long axis and anterior-posterior axis, suggesting a balance of forces along these axes, yet it moves significantly toward the interventricular septum, presumably counterbalancing the opposite translation during systole of the right ventricular (RV) center of volume.(ABSTRACT TRUNCATED AT 400 WORDS)

摘要

为了量化移植人心左心室(LV)中层壁的三维区域动态以及左心室腔的质心和横截面形状,在15例患者心脏移植时,将12个微型不透射线的钽标记物植入供体心脏的左心室中层壁。术后晚期(平均术后52天)的立体电影血管造影术能够在整个心动周期以16.7毫秒的间隔对左心室前壁、下壁、侧壁和间隔区域多个部位的三维坐标进行计算机辅助测量。在清醒仰卧的患者中,从左心室最大容积到最小容积,游离壁标记物的组平均位移范围为0.80至1.24厘米,方向指向左心室内部,而间隔壁标记物的位移明显较小,分别为0.46和0.34厘米(p<0.01),方向背离左心室内部。沿间隔-侧壁轴的这种位移分量在间隔(0.19和0.20厘米)也明显小于游离壁(范围为0.32至0.97厘米)(p<0.01)。左心室横截面不是圆形,前-下维度(分别在最大和最小容积时为7.18±0.66和6.13±0.79厘米)明显大于间隔-侧壁维度(5.78±0.65和5.12±0.48厘米)(p<0.01),产生不变的横向椭圆形左心室偏心率(0.58±0.13)。左心室容积中心在左心室长轴或前-下轴方向上从最大容积到最小容积没有明显变化,但在间隔-侧壁轴上有明显变化(0.55±0.23厘米,p<0.01)。我们得出结论:1)在固定的外部参考系统中观察,移植人心室间隔的中层壁部位移动反常,但与左心室游离壁中层壁部位的三维动态相比相对固定;2)移植人心左心室的横向横截面形状明显为椭圆形,在左心室最大和最小容积时前后维度明显大于间隔-侧壁维度;3)移植人心左心室的容积中心在左心室长轴和前后轴方向上非常稳定,表明沿这些轴的力平衡,但它明显向室间隔移动,推测是为了平衡右心室容积中心在收缩期的相反位移。(摘要截短于400字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验