Department of Orthopaedics, University of Cincinnati, Cincinnati, OH 45267, USA.
J Shoulder Elbow Surg. 2013 Sep;22(9):e7-13. doi: 10.1016/j.jse.2012.12.035. Epub 2013 Mar 6.
Hills-Sachs lesions are commonly associated with anterior shoulder dislocations and can be a source of recurrent instability. Studies have shown that, even after soft tissue repair of a Bankart lesion, there is still a risk for redislocation in a patient with significant bony defects. The purpose of this study is to ascertain whether balloon humeroplasty is an effective technique of reducing acute Hill-Sachs defect in a cadaveric model.
Eighteen cadaveric humerii dissected free of soft tissue were used for this study. Hill-Sachs lesions were created in a reproducible manner in the anatomical posterolateral aspect of the head with a mallet edge. An inflatable balloon tamp (balloon, IBT) was used to reduce the lesion via a small transcortical window. Cement was used to fill the void created by the balloon. We utilized computed tomography (CT) to collect volume data of each humeral head pre- and post-procedure. From this data, we calculated the volume of the Hill-Sachs defect and the percent corrected. A paired t test was performed to analyze the data statistically.
The average prereduction Hill-Sachs defect volume was 1515.5 mm(3). The average post-reduction lesion residual volume was 31 mm(3) with 99.3% reduction to the original humeral head volume. The Hill-Sachs lesion reduction was statistically significant with P value of .0004.
Balloon humeroplasty proved to be an effective technique for reducing Hill-Sachs lesions in a cadaveric model. This technique may be used as an adjunct to arthroscopic versus open Bankart procedure for engaging acute Hill-Sachs lesions.
Hills-Sachs 损伤通常与肩关节前脱位有关,可能是复发性不稳定的原因。研究表明,即使 Bankart 损伤的软组织修复后,对于有明显骨缺损的患者,仍存在再脱位的风险。本研究旨在确定球囊肱骨头成形术是否是减少解剖后外侧头急性 Hill-Sachs 缺损的有效技术。
本研究使用 18 个游离软组织的尸体肱骨头进行研究。使用锤缘在解剖后外侧头部以可重复的方式创建 Hill-Sachs 损伤。通过小皮质窗使用可膨胀球囊填塞(球囊,IBT)来减少病变。使用水泥填充球囊产生的空隙。我们使用计算机断层扫描(CT)收集每个肱骨头术前和术后的体积数据。根据这些数据,我们计算了 Hill-Sachs 缺损的体积和纠正百分比。使用配对 t 检验对数据进行统计学分析。
平均术前 Hill-Sachs 缺损体积为 1515.5mm3。平均术后残留病变体积为 31mm3,原始肱骨头体积减少 99.3%。Hill-Sachs 病变的减少具有统计学意义,P 值为.0004。
球囊肱骨头成形术被证明是一种减少尸体模型中 Hill-Sachs 损伤的有效技术。该技术可作为关节镜与开放式 Bankart 手术治疗急性 Hill-Sachs 损伤的辅助手段。