Synthetic peptide antigens elicit monoclonal and polyclonal antibodies to cytochrome P450 IA2.

作者信息

Myers M J, Liu G, Miller H, Gelboin H V, Robinson R C, Friedman F K

机构信息

Laboratory of Molecular Carcinogenesis, National Cancer Institute, Bethesda, MD 20892.

出版信息

Biochem Biophys Res Commun. 1990 May 31;169(1):171-6. doi: 10.1016/0006-291x(90)91450-7.

Abstract

Two peptide sequences from cytochrome P450 IA2 were synthesized, coupled to ovalbumin and used as antigens to generate anti-peptide monoclonal and polyclonal antibodies. Antisera to both peptides reacted with rat IA2 but not the structurally similar IA1 form as determined by enzyme-linked immunosorbent assay. However, antisera to both peptides detected both rat IA2 and IA1 on immunoblots. In addition immunoblots of human liver microsomes revealed that both antisera recognized human IA2, but not IA1. Monoclonal antibodies generated against one of the peptides recognized rat IA2 and IA1 but did not detect human IA2. These results demonstrate the utility of anti-peptide antisera as a practical approach for the generation of P450 specific antibodies.