Suppr超能文献

[利用智能手机测定放射性]

[Determination of radioactivity by smartphones].

作者信息

Hartmann H, Freudenberg R, Andreeff M, Kotzerke J

机构信息

Klinik und Poliklinik für Nuklearmedizin, Universitätsklinikum Carl Gustav Carus, an der Technischen Universität Dresden, Fetscherstraße 74, 01307 Dresden.

出版信息

Nuklearmedizin. 2013;52(2):64-70. doi: 10.3413/Nukmed-0526-12-08.

Abstract

UNLABELLED

The interest in the detection of radioactive materials has strongly increased after the accident in the nuclear power plant Fukushima and has led to a bottleneck of suitable measuring instruments. Smartphones equipped with a commercially available software tool could be used for dose rate measurements following a calibration according to the specific camera module.

AIM

We examined whether such measurements provide reliable data for typical activities and radionuclides in nuclear medicine.

METHODS

For the nuclides 99mTc (10 - 1000 MBq), 131I (3.7 - 1800 MBq, therapy capsule) and 68Ga (50 - 600 MBq) radioactivity with defined geometry in different distances was measured. The smartphones Milestone Droid 1 (Motorola) and HTC Desire (HTC Corporation) were compared with the standard instruments AD6 (automess) and DoseGUARD (AEA Technology).

RESULTS

Measurements with the smartphones and the other devices show a good agreement: linear signal increase with rising activity and dose rate. The long time measurement (131I, 729 MBq, 0.5 m, 60 min) demonstrates a considerably higher variation (by 20%) of the measured smartphone data values compared with the AD6. For low dose rates (< 1 µGy/h), the sensitivity decreases so that measurements of e. g. the natural radiation exposure do not lead to valid results. The calibration of the camera responsivity for the smartphone has a big influence on the results caused by the small detector surface of the camera semiconductor.

CONCLUSIONS

With commercial software the camera module of a smartphone can be used for the measurement of radioactivity. Dose rates resulting from typical nuclear medicine procedures can be measured reliably (e. g., dismissal dose after radioiodine therapy). The signal shows a high correlation to measured values of conventional dose measurement devices.

摘要

未标注

福岛核电站事故后,对放射性物质检测的关注度大幅提高,导致适用测量仪器出现瓶颈。配备市售软件工具的智能手机经根据特定相机模块校准后,可用于剂量率测量。

目的

我们研究了此类测量能否为核医学中的典型活动和放射性核素提供可靠数据。

方法

对核素99mTc(10 - 1000MBq)、131I(3.7 - 1800MBq,治疗胶囊)和68Ga(50 - 600MBq)在不同距离下具有确定几何形状的放射性进行测量。将智能手机摩托罗拉里程碑Droid 1和HTC Desire与标准仪器AD6(automess)和剂量防护仪(AEA技术公司)进行比较。

结果

智能手机与其他设备的测量结果显示出良好的一致性:随着活度和剂量率升高,信号呈线性增加。长时间测量(131I,729MBq,0.5m,60分钟)表明,与AD6相比,智能手机测量数据值的变化明显更高(达20%)。对于低剂量率(<1µGy/h),灵敏度降低,因此例如自然辐射暴露的测量无法得出有效结果。由于相机半导体探测器表面较小,智能手机相机响应度的校准对结果有很大影响。

结论

借助商业软件,智能手机的相机模块可用于放射性测量。典型核医学程序产生的剂量率可得到可靠测量(例如,放射性碘治疗后的出院剂量)。该信号与传统剂量测量设备的测量值高度相关。