Rani Asha, Singh Surinder, Duggal Vikas
Department of Applied Sciences, Ferozpur College of Engineering and Technology, Ferozshah, Ferozpur 142052, India.
Radiat Prot Dosimetry. 2013;156(1):118-24. doi: 10.1093/rpd/nct041. Epub 2013 Mar 17.
The measurement of indoor radon concentrations were performed in the dwellings of the Punjab and Himachal Pradesh, India by using LR-115 type II Solid-State Nuclear Track Detectors in the bare mode. The annual average indoor radon concentrations in the dwellings are found to vary from 114 to 400 Bq m(-3) with an average of 194 Bq m(-3). In ∼22 % of the dwellings the indoor radon activity concentration values lies in the range of action level (200-300 Bq m(-3)) and in ∼11 % of the dwellings above the upper limit of action level recommended by the International Commission on Radiological Protection (ICRP). The annual effective dose (AED) varies from 2.88 to 10.08 mSv with an average of 4.88 mSv. In most of the villages, the AED lies in the range of action level (3-10 mSv) recommended by the ICRP. The seasonal variation in indoor radon reveals the maximum values in winter and minimum in summer. The winter/summer ratio of indoor radon ranges from 1.15 to 1.62 with an average of 1.31. Analysis of ventilation conditions reveal that the indoor radon concentration values are more in poorly ventilated dwellings compared with the well-ventilated ones.
在印度旁遮普邦和喜马偕尔邦的住宅中,使用裸模式的LR - 115 II型固态核径迹探测器对室内氡浓度进行了测量。住宅中的年平均室内氡浓度在114至400 Bq m(-3)之间变化,平均为194 Bq m(-3)。在约22%的住宅中,室内氡活度浓度值处于行动水平范围内(200 - 300 Bq m(-3)),在约11%的住宅中高于国际放射防护委员会(ICRP)推荐的行动水平上限。年有效剂量(AED)在2.88至10.08 mSv之间变化,平均为4.88 mSv。在大多数村庄,AED处于ICRP推荐的行动水平范围内(3 - 10 mSv)。室内氡的季节变化显示冬季值最高,夏季最低。室内氡的冬夏比在1.15至1.62之间,平均为1.31。通风条件分析表明,与通风良好的住宅相比,通风不良的住宅中室内氡浓度值更高。