Department of Pathology, Brigham and Women's Hospital and Harvard Medical School, Boston, MA 02115, USA.
Am J Clin Pathol. 2013 May;139(5):672-81. doi: 10.1309/AJCP4HIFSHMO9WTK.
Epithelial malignancies frequently metastasize to the serous cavities and result in symptomatic effusions. Cytology has high specificity but moderate sensitivity for the diagnosis of a malignant effusion. We developed and validated a simple, rapid, 3-color flow cytometric panel using the adhesion molecule Ber-EP4 to detect epithelial cells in effusions. One hundred ninety-five consecutive benign and malignant effusions received for routine cytologic examination were analyzed. Eighty-three fluid specimens were benign and 76 were malignant as judged by follow-up data. Ber-EP4-positive cells were detected with flow cytometry in 89.3% of malignant effusions. The sensitivity and specificity of flow cytometry was 88.15% and 97.64% compared with 73.68% and 100% on cytologic examination alone for the presence of a malignant effusion. Flow cytometry is a useful adjunct to cytology for the diagnosis of a malignant effusion and is particularly useful if the cytologic diagnosis is atypical/suspicious or if the cytologic preparations are hypocellular or hemorrhagic.
上皮性恶性肿瘤常转移至浆膜腔,导致有症状的渗出液。细胞学检查对恶性渗出液的诊断具有高特异性和中等敏感性。我们开发并验证了一种简单、快速、使用黏附分子 Ber-EP4 的三色流式细胞术检测渗出液中上皮细胞的面板。对 195 例连续的良性和恶性渗出液进行了常规细胞学检查分析。根据随访资料,83 例液体标本为良性,76 例为恶性。流式细胞术检测到 89.3%的恶性渗出液中存在 Ber-EP4 阳性细胞。与单独细胞学检查相比,流式细胞术对恶性渗出液的诊断具有 88.15%的敏感性和 97.64%的特异性,而敏感性和特异性分别为 73.68%和 100%。流式细胞术是细胞学诊断恶性渗出液的有用辅助手段,如果细胞学诊断不典型/可疑,或者细胞学标本细胞稀少或有出血,流式细胞术尤其有用。