Suppr超能文献

消毒预处理后两种树脂水门汀与牙本质的粘结强度:铒铬:钇钪镓石榴石激光与化学抗菌剂的效果比较

Bond strength of two resin cements to dentin after disinfection pretreatment: effects of Er,Cr:YSGG laser compared with chemical antibacterial agent.

作者信息

Shafiei Fereshteh, Fekrazad Reza, Kiomarsi Nazanin, Shafiei Ehsan

机构信息

Department of Operative Dentistry, Dental Faculty, Shiraz University of Medical Sciences, Shiraz, Iran.

出版信息

Photomed Laser Surg. 2013 May;31(5):206-11. doi: 10.1089/pho.2012.3400. Epub 2013 Apr 19.

Abstract

OBJECTIVE

This study compared the effects of two disinfection procedures (2% chlorhexidine [CHX] solution versus Er,Cr:YSGG laser irradiation) on the shear bond strength of ED primer II/Panavia F2.0 (ED/P) and Excite DSC/Variolink N (Ex/V).

BACKGROUND DATA

Different methods are used for cavity disinfection prior to adhesive cementation, which may influence the bonding ability of resin cements.

METHODS

Flat dentin surfaces were prepared on 100 extracted premolars and randomly divided into 10 groups. In the eight experimental groups, indirect composite samples were cemented with either ED/P or Ex/V under three disinfecting conditions on the dentin surface as follows: (1) CHX application before ED primer II/ after etching, (2) wet laser irradiation (Er,Cr:YSGG laser, 20 Hz, 0.75 W, 15% water +15% air), (3) dry laser irradiation with no water and air cooling. The control groups had no disinfectant application. After 24 h water storage, bond strength test was performed. The data (MPa) were analyzed using two way ANOVA and Tukey tests.

RESULTS

The lowest and highest bond strengths were obtained by dry laser and wet laser (10.18±2.67 and 17.36±2.94 for ED/P, 9.64±2.66 and 20.07±3.36 for Ex/V, respectively). For each cement, two-by-two comparisons of four groups revealed significant differences only for dry laser with others (p<0.001).

CONCLUSIONS

The use of CHX and Er,Cr:YSGG laser at the low fluences with water/air cooling as the antibacterial agents does not adversely influence the bonding ability of the etch-and-rinse and the self-etch cements.

摘要

目的

本研究比较了两种消毒程序(2%氯己定[CHX]溶液与铒铬:钇-钪-镓石榴石激光照射)对ED底漆II/帕纳维亚F2.0(ED/P)和Excite DSC/Variolink N(Ex/V)剪切粘结强度的影响。

背景数据

在粘结树脂水门汀之前,采用不同的方法进行窝洞消毒,这可能会影响树脂水门汀的粘结能力。

方法

在100颗拔除的前磨牙上制备平坦的牙本质表面,并随机分为10组。在8个实验组中,间接复合样本在牙本质表面的三种消毒条件下,用ED/P或Ex/V粘结,具体如下:(1)在蚀刻后应用ED底漆II之前应用CHX,(2)湿激光照射(铒铬:钇-钪-镓石榴石激光,20Hz,0.75W,15%水+15%空气),(3)无水和空气冷却的干激光照射。对照组不应用消毒剂。储存24小时水后,进行粘结强度测试。使用双向方差分析和Tukey检验分析数据(MPa)。

结果

干激光和湿激光获得的粘结强度最低和最高(ED/P分别为(10.18±2.67和17.36±2.94,Ex/V分别为9.64±2.66和20.07±3.36)。对于每种水门汀,四组的两两比较仅显示干激光与其他组有显著差异(p<0.001)。

结论

使用CHX和低能量的铒铬:钇-钪-镓石榴石激光并以水/空气冷却作为抗菌剂,不会对酸蚀冲洗粘结剂和自酸蚀粘结剂的粘结能力产生不利影响。

相似文献

本文引用的文献

10
Chlorhexidine preserves dentin bond in vitro.洗必泰在体外可保留牙本质粘结。
J Dent Res. 2007 Jan;86(1):90-4. doi: 10.1177/154405910708600115.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验