Non-anticoagulant hemodialysis is conducted occasionally at limited numbers of hospitals on an empirical basis. This study examines the efficacy of polysulfone and vitamin E-bonded polysulfone dialyzer for non-anticoagulant hemodialysis. These dialyzers were assigned one after the other for a vintage hemodialysis patient complicated with uncontrollable bleeding. The patient's vital and console data throughout non-anticoagulant hemodialysis were monitored serially. Both dialyzers were reasonably applicable to hemodialysis without major clotting. The scheduled treatment period was completed. Vitamin E-bonded polysulfone dialyzer was superior to non-anticoagulant hemodialysis based on venous pressure observed during treatment.

摘要

非抗凝性血液透析偶尔在少数医院凭经验进行。本研究旨在检验聚砜膜和维生素 E 键合聚砜膜透析器在非抗凝性血液透析中的疗效。一位并发难以控制出血的陈旧性血液透析患者先后使用这两种透析器进行治疗。患者在非抗凝性血液透析过程中的重要生命体征和控制台数据被连续监测。两种透析器在无严重凝血的情况下均可合理应用于血液透析。预定的治疗期完成。根据治疗过程中的静脉压,维生素 E 键合聚砜膜透析器优于非抗凝性血液透析。