使用 Elekta 设备行海马保护全脑放疗。

Hippocampal-sparing whole-brain radiotherapy using Elekta equipment.

机构信息

Division of Oncology, Rambam Health Care Campus, Haifa, Israel.

出版信息

J Appl Clin Med Phys. 2013 May 6;14(3):4205. doi: 10.1120/jacmp.v14i3.4205.

Abstract

The purpose of this study was to evaluate the feasibility of hippocampal-sparing whole-brain radiotherapy (HS WBRT) using the Elekta Infinity linear accelerator and Monaco treatment planning system (TPS). Ten treatment plans were created for HS-WBRT to a dose of 30 Gy (10 fractions). RTOG 0933 recommendations were applied for treatment planning. Intensity-modulated radiotherapy (IMRT) plans for the Elekta Infinity linear accelerator were created using Monaco 3.1 TPS-based on a nine-field arrangement and step-and-shoot delivery method. Plan evaluation was performed using D2% and D98% for the whole-brain PTV (defined as whole brain excluding hippocampus avoidance region), D100% and maximum dose to the hippocampus, and maximum dose to optic nerves and chiasm. Homogeneity index (HI) defined as (D2%-D98%)/Dmedian was used to quantify dose homogeneity in the PTV. The whole-brain PTV D2% mean value was 37.28 Gy (range 36.95-37.49Gy), and D98% mean value was 25.37 Gy (range 25.40-25.89 Gy). The hippocampus D100% mean value was 8.37 Gy (range 7.48-8.97 Gy) and the hippocampus maximum dose mean value was 14.35 Gy (range 13.48-15.40 Gy). The maximum dose to optic nerves and optic chiasm for all patients did not exceed 37.50 Gy. HI mean value was 0.36 (range 0.34-0.37). Mean number of segments was 105 (range 88-122) and mean number of monitor units was 1724 (range 1622-1914). Gamma evaluation showed that all plans passed 3%, 3 mm criteria with more than 99% of the measured points. These results indicate that Elekta equipment (Elekta Infinity linac and Monaco TPS) can be used for HS WBRT planning according to compliance criteria defined by the RTOG 0933 protocol.

摘要

本研究旨在评估使用 Elekta 无限直线加速器和 Monaco 治疗计划系统(TPS)进行海马保留全脑放疗(HS-WBRT)的可行性。为 30 Gy(10 个分次)的 HS-WBRT 制定了 10 个治疗计划。根据 RTOG 0933 建议书进行治疗计划。使用 Monaco 3.1 TPS 基于九野排列和步进式交付方法为 Elekta 无限直线加速器创建了调强放疗(IMRT)计划。使用 D2%和 D98%评估整个脑 PTV(定义为除海马回避区之外的整个脑),D100%和海马最大剂量以及视神经和视交叉的最大剂量的计划。均匀性指数(HI)定义为(D2%-D98%)/Dmedian 用于量化 PTV 中的剂量均匀性。整个脑 PTV D2%平均值为 37.28 Gy(范围为 36.95-37.49Gy),D98%平均值为 25.37 Gy(范围为 25.40-25.89 Gy)。海马 D100%平均值为 8.37 Gy(范围为 7.48-8.97 Gy),海马最大剂量平均值为 14.35 Gy(范围为 13.48-15.40 Gy)。所有患者的视神经和视交叉最大剂量均不超过 37.50 Gy。HI 的平均值为 0.36(范围为 0.34-0.37)。段数平均值为 105(范围 88-122),监视器单位数平均值为 1724(范围 1622-1914)。伽马评估显示,所有计划均通过了 3%,3 mm 标准,超过 99%的测量点符合标准。这些结果表明,Elekta 设备(Elekta 无限直线加速器和 Monaco TPS)可以根据 RTOG 0933 协议定义的符合标准进行 HS-WBRT 规划。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9884/5714429/d260a2405f43/ACM2-14-113-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验