To present a case report about 57-years-old woman with hypoxemia, multiple pulmonary arteriovenous (AV) malformations and lips teleangiectasis where the right-to-left shunt quantification was assessed by means of whole body scintigraphy with 9mTc-labelled human macro-aggregated albumin (MAA).
A 57-years-old woman underwent X-ray and bolus enhanced lung CT for dyspnoea, hypoxemia and cyanosis. A multiple intrapulmonary arteriovenous malformations were detected. The whole-body 99mTc-MAA scintigraphy for the right-to-left shunt quantification was performed. The whole-body scintigraphy in anterior and posterior view was started after intravenous application of 185 MBq 99mTc-MAA. The double-head gamma camera Infinia (General Electric Medical Systems--GE MS) with infrared body countouring and the large field of view was used. The Gamma camera was fitted with low-energy, high resolution, parallel-hole collimator. Images were evaluated by processing system Xeleris (GE MS).
The whole-body 99mTc-MAA scintigraphy revealed significant R-L shunt and uptake of radiotracer in extrapulmonary organs (brain, kidney, spleen). The right-to-left shunt ratio was 36%. The woman underwent successful percutaneous transcatheter microembolization treatment. After treatment the woman underwent the next 99mTc-MAA whole-body scintigraphy and the R-L shunt ratio decreased to 17%.
The 99mTc-MAA whole-body scintigraphy assessed the right-to-left shunt ratio and improved the management of patients with multiple intrapulmonary A-V malformations. The next 99mTc-MAA scintigraphy after the percutaneous transcatheter microembolization of multiple intrapulmonary A-V malformations confirmed success of treatment.
报告一例57岁女性患者,患有低氧血症、多发性肺动静脉畸形和唇部毛细血管扩张症,通过使用9mTc标记的人聚合白蛋白(MAA)进行全身闪烁扫描评估其右向左分流情况。
一名57岁女性因呼吸困难、低氧血症和发绀接受了X线和团注增强肺部CT检查。检测到多发性肺内动静脉畸形。进行了全身99mTc-MAA闪烁扫描以量化右向左分流。静脉注射185MBq 99mTc-MAA后开始进行前后位全身闪烁扫描。使用配备红外人体轮廓和大视野的双头伽马相机Infinia(通用电气医疗系统公司 - GE MS)。伽马相机配备低能、高分辨率、平行孔准直器。图像由处理系统Xeleris(GE MS)评估。
全身99mTc-MAA闪烁扫描显示存在明显的右向左分流,且放射性示踪剂在肺外器官(脑、肾、脾)摄取。右向左分流率为36%。该女性接受了成功的经皮经导管微栓塞治疗。治疗后该女性再次进行了99mTc-MAA全身闪烁扫描,右向左分流率降至17%。
99mTc-MAA全身闪烁扫描可评估右向左分流率,改善多发性肺内动静脉畸形患者的管理。多发性肺内动静脉畸形经皮经导管微栓塞治疗后的再次99mTc-MAA闪烁扫描证实了治疗的成功。