Suppr超能文献

五毫米球囊穿刺部位疝:两例报告及文献复习。

Five-millimeter balloon trocar site herniation: report of two cases and review of literature.

机构信息

Department of Obstetrics and Gynecology, Mount Sinai Hospital, New York, New York.

出版信息

J Minim Invasive Gynecol. 2013 Sep-Oct;20(5):723-6. doi: 10.1016/j.jmig.2013.04.012. Epub 2013 May 25.

Abstract

Trocar site herniation is a well-known potential complication of minimally invasive surgery. We present the cases of two herniations after use of 5-mm non-bladed balloon trocars. In both patients, surgical management was required, with no subsequent sequelae to date. The hernias were attributed to excessive fascial stretching and compression by the balloon. We recommend full-thickness closure of 5-mm ports if a balloon is used or if there was extensive intraoperative manipulation.

摘要

套管部位疝是微创外科中一种众所周知的潜在并发症。我们报告两例使用 5mm 无刃球囊套管后发生的疝。两例患者均需要手术治疗,目前尚无后续后遗症。疝的发生归因于球囊对筋膜的过度拉伸和压迫。如果使用球囊或术中进行了广泛的操作,我们建议对 5mm 套管进行全层缝合。