Suppr超能文献

通过非侵入性方法测量颅内压升高:文献综述。

Measuring elevated intracranial pressure through noninvasive methods: a review of the literature.

机构信息

Department of Neurosurgery, University Hospital of Lund, Lund, Sweden.

出版信息

J Neurosurg Anesthesiol. 2013 Oct;25(4):372-85. doi: 10.1097/ANA.0b013e31829795ce.

Abstract

Elevated intracranial pressure (ICP) is an important cause of secondary brain injury, and a measurement of ICP is often of crucial value in neurosurgical and neurological patients. The gold standard for ICP monitoring is through an intraventricular catheter, but this invasive technique is associated with certain risks. Intraparenchymal ICP monitoring methods are considered to be a safer alternative but can, in certain conditions, be imprecise due to zero drift and still require an invasive procedure. An accurate noninvasive method to measure elevated ICP would therefore be desirable. This article is a review of the current literature on noninvasive methods for measuring and evaluating elevated ICP. The main focus is on studies that compare noninvasively measured ICP with invasively measured ICP. The aim is to provide an overview of the current state of the most common noninvasive techniques available. Several methods for noninvasive measuring of elevated ICP have been proposed: radiologic methods including computed tomography and magnetic resonance imaging, transcranial Doppler, electroencephalography power spectrum analysis, and the audiological and ophthalmological techniques. The noninvasive methods have many advantages, but remain less accurate compared with the invasive techniques. None of the noninvasive techniques available today are suitable for continuous monitoring, and they cannot be used as a substitute for invasive monitoring. They can, however, provide a reliable measurement of the ICP and be useful as screening methods in select patients, especially when invasive monitoring is contraindicated or unavailable.

摘要

颅内压升高(ICP)是继发性脑损伤的一个重要原因,ICP 的测量在神经外科和神经科患者中通常具有至关重要的价值。ICP 监测的金标准是通过脑室内导管进行,但这种有创技术存在一定风险。脑实质 ICP 监测方法被认为是一种更安全的替代方法,但在某些情况下,由于零点漂移,可能会不够精确,并且仍然需要进行有创操作。因此,人们希望有一种准确的、非侵入性的方法来测量升高的 ICP。本文综述了目前关于测量和评估升高的 ICP 的非侵入性方法的文献。主要重点是比较非侵入性测量的 ICP 与侵入性测量的 ICP 的研究。目的是提供目前最常见的非侵入性技术的概述。已经提出了几种用于测量升高的 ICP 的非侵入性方法:包括计算机断层扫描和磁共振成像在内的放射学方法、经颅多普勒、脑电图功率谱分析以及听力学和眼科学技术。非侵入性方法具有许多优点,但与侵入性技术相比,准确性仍然较低。目前尚无一种非侵入性技术适合连续监测,不能作为侵入性监测的替代方法。然而,它们可以提供 ICP 的可靠测量值,并可作为特定患者的筛选方法,尤其是在侵入性监测禁忌或不可用时。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验